When programming is underway, a further progress
report, Programming block n of 7 yy%, is displayed.
When recovery is complete, Recovery complete,
remove the diskette and return boot block switch
to the off position before rebooting is displayed.
6. Remove the flash diskette from the diskette drive.
7. Turn the server off.
8. Remove the jumper on the boot-block jumper block or
move pins 2 and 3 to return to normal startup mode.
9. Restart the server. The system should start up
normally.

Troubleshooting the Ethernet controller

This section provides troubleshooting information for
problems that might occur with the 10/100 Mbps Ethernet
controller.

Network connection problems

If the Ethernet controller cannot connect to the network,
check the following:
v Make sure that the cable is installed correctly.
The network cable must be securely attached at all
connections. If the cable is attached but the problem
persists, try a different cable.
If you set the Ethernet controller to operate at 100
Mbps, you must use Category 5 cabling.
If you directly connect two workstations (without a hub),
or if you are not using a hub with X ports, use a
crossover cable.
Note: To determine whether a hub has an X port, check
the port label. If the label contains an X, the hub
has an X port.
v Determine if the hub supports auto-negotiation. If not, try
configuring the integrated Ethernet controller manually to
match the speed and duplex mode of the hub.
v Check the Ethernet controller lights on the operator
information panel.
These lights indicate whether a problem exists with the
connector, cable, or hub.
– The Ethernet Link Status light illuminates when the
Ethernet controller receives a LINK pulse from the
hub. If the light is off, there might be a bad connector
or cable, or a problem with the hub.
– The Ethernet Transmit/Receive Activity light
illuminates when the Ethernet controller sends or
receives data over the Ethernet Network. If the
Ethernet Transmit/Receive Activity light is off, make
24