Undetermined Problems - IBM 8480 - Eserver xSeries 205 Maintenance And Troubleshooting Manual

Hardware maintenance manual
Hide thumbs Also See for 8480 - Eserver xSeries 205:
Table of Contents

Advertisement

Undetermined problems

Use the information in this section if the diagnostic tests did not identify the failure,
the devices list is incorrect, or the system is inoperative.
Notes:
1. Damaged data in CMOS can cause undetermined problems.
2. Damaged data in BIOS code can cause undetermined problems.
Check the LEDs on all the power supplies. If the LEDs indicate the power supplies
are working correctly, complete the following steps:
1. Turn off the server.
2. Be sure the server is cabled correctly.
3. Remove or disconnect the following devices (one at a time) until you find the
4. Turn on the server. If the problem remains, suspect the following FRUs in the
Notes:
1. If the problem goes away when you remove an adapter from the system and
2. If you suspect a networking problem and all the system tests pass, suspect a
108
IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
failure (turn on the server and reconfigure each time):
Any external devices
Surge suppressor device (on the server)
Modem, printer, mouse, or non-IBM devices
Each adapter
Drives
Memory modules (minimum requirement = 256 MB (2 banks of 128 MB
DIMMs))
Note: Minimum operating requirements are:
a. One power supply
b. Power cage assembly, if installed.
c. System board
d. One microprocessor and VRM
e. Memory module (with a minimum of two 128 MB DIMMs)
order listed:
Power supply
Power cage assembly, if installed
System board
replacing that adapter does not correct the problem, suspect the system board.
network cabling problem external to the system.

Advertisement

Table of Contents
loading

This manual is also suitable for:

848052xEserver xseries 205 type 8480

Table of Contents