To migrate the CPU to the spare system board:
1.
Take the iLO label off the system board toe tag and place it over the iLO toe tag on the front
panel.
2.
Install the spare system board.
CAUTION:
replacing the system board.
3.
Install the CPUs and heat sink or CPU heat sink module the system board
(page
37)).
4.
Install all components removed from the failed system board.
5.
Install the access panel
6.
Install the power supplies
7.
Power up the server.
NOTE:
board.
CAUTION:
default. When the original components are re-installed on the replacement board and the system
is booted to UEFI, the saupdate utility must be used to re-enable the RAID configuration if the
original server blade was using the RAID functionality. See
instructions on using the saupdate utility.
After you replace the system board, you must to set the SAS mode to RAID if that was your previous
configuration.
1.
During the server startup, wait for UEFI Front Page, press S or s to launch the UEFI Shell.
2.
Get the saupdate.efi utility tool.
3.
Enter saupdate.efi set_mode 0:1:0:0 raid to change the SAS mode to RAID.
4.
Enter saupdate.efi get_mode 0:1:0:0 to verify the SAS mode is set to RAID.
After you replace the system board, you must port over the server serial number, product number
and UUID. Labels on the server indicates these numbers.
1.
Login to ILO 3 MP, by using SSH, for example.
2.
Access the MP Main Menu.
3.
Enter CM at the hpiLO-> prompt.
4.
Enter sysset at the CM:hpiLO> prompt, and it will show the system information
5.
To change the serial number:
a.
Enter sysset -serial <serial number> at the CM:hpiLO-> prompt.
b.
Enter the associated password, and press Enter.
6.
To change product number (default is for the data center server):
a.
Enter sysset -prodnum <product number> at the CM:hpiLO-> prompt.
b.
Enter the associated password, and press Enter.
7.
To change the UUID:
a.
Enter sysset -uuid <uuid> at the MP:CM -> prompt.
b.
Enter the associated password and press Enter
8.
Reset iLO MP by entering xd -r -nc at the CM:hpiLO-> prompt.
124 Removal and replacement procedures
The pins on the CPU socket are very fragile. Any damage to them may require
("Access panel" (page
("Hot-swap power supply" (page
Install all components with the same configuration that was used on the failed system
Replacement system boards are shipped with the RAID controller in HBA mode by
107)).
106)).
"SAS disk setup" (page 132)
("Installing a CPU"
for