Brocade Communications Systems 8 Command Reference Manual page 780

Fabric os command reference manual supporting fabric
Hide thumbs Also See for 8:
Table of Contents

Advertisement

2
portShow
Operands
This command has the following port operands:
slot
port
-i index1[-index2]
Examples
To display the current state of a port:
748
For bladed systems only, specifies the slot number of the port to be displayed,
followed by a slash (/).
Specifies the number of the port to be displayed, relative to its slot for bladed
systems. Use switchShow for a listing of valid port numbers.
Specifies a port or a range of ports identified by port index numbers. You can
specify multiple index ranges separated by a space, for example, 33-38
40-60. Port indexes are supported only if PortSwap is disabled. They are not
supported on GbE ports and configured F_Port trunks. Use the -i option
without a port index argument to display the portSwap status, or alternately
use portSwapShow.
switch:admin> portshow 43
portIndex:
43
portName:
portHealth: HEALTHY
Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x1000490b
LOGICAL_ONLINE LOGIN LED
portType:
18.0
POD Port: Port is licensed
portState: 1
Online
Protocol: FC
portPhys:
6
In_Sync
port generation number:
state transition count:
portId:
230100
portIfId:
43020009
portWwn:
20:2b:00:05:1e:07:c7:26
portWwn of device(s) connected:
Distance:
normal
portSpeed: N4Gbps
LE domain: 0
FC Fastwrite: OFF
Interrupts:
0
Unknown:
0
Lli:
11
Proc_rqrd:
9877
Timed_out:
0
Rx_flushed:
0
Tx_unavail:
0
Free_buffer:
0
Overrun:
0
Suspended:
0
Parity_err:
0
2_parity_err:
0
CMI_bus_err:
0
switch:admin>
PRESENT ACTIVE E_PORT T_PORT T_MASTER G_PORT U_PORT
portScn:
16
0
1
Link_failure: 0
Loss_of_sync: 1
Loss_of_sig:
2
Protocol_err: 0
Invalid_word: 14
Invalid_crc:
0
Delim_err:
0
Address_err:
0
Lr_in:
2
Lr_out:
0
Ols_in:
0
Ols_out:
1
E_Port
Trunk master port
Frjt:
Fbsy:
Fabric OS Command Reference
53-1001764-02