Operands
This command has the following operands:
slot
port
F_Port Top Talker commands:
--add
--show
--delete
Fabric Mode Top Talker commands:
--add fabricmode
--show
--delete fabricmode
Examples
To add an F_Port Top Talker to blade 1 port 2 (which should be an F_Port):
To delete the F_Port Top Talker:
Fabric OS Command Reference
53-1001764-02
For bladed systems only, specifies the slot number of the port on which to
install Top Talkers, followed by a slash (/).
Specifies the number of the port on which the Top Talker is to be installed,
relative to its slot for bladed systems. Use switchShow for a list of valid ports.
Installs the Top Talker monitor on a specified F_Port.
egress | ingress
Used with the --add option to specify the direction in which the traffic is
monitored as incoming or outgoing. This operand is required.
Displays the top talking flows on a specified port.
number of top talking flows
Specifies "n" top talking flows. Valid values are between 1 and 32. If a value
greater than 32 is entered, Top Talker displays counters for only 32 flows and
a warning message. This operand is optional; if omitted, the command
displays the top 8 flows.
wwn | pid
Specifies the output display as either WWN or PID format. This operand is
optional. If omitted, the command displays in WWN format.
Deletes an existing Top Talker monitor on a specified F_Port.
Installs the Top Talker monitor on all switches in the fabric. When a new
switch joins the fabric, this command must be run again on the switch. The TT
configuration information is not propagated automatically to the new switch.
Displays the Top Talking flows on the switch for a given domain ID.
dom dom_id
Specifies the domain ID for the flow display.
number of top talking flows
Specifies "n" Top Talking flows. Valid values are between 1 and 32. If a value
greater than 32 is entered, Top Talker displays counters for only 32 flows and
a warning message. This operand is optional; if omitted, the command
displays the top 8 flows.
wwn | pid
Specifies display as either WWN or PID format. This operand is optional; if
omitted, the command displays in WWN format.
Deletes the Fabric Mode Top Talker.
Switch:admin> perfttmon --add ingress 1/2