POST Error Messages
1789-Drive Not
Responding,
Physical Drive
Check cables
or replace
physical drive
X.
Select "F1" to
continue -
drive array will
remain
disabled.
Select "F2" to
fail drive(s)
that are not
responding -
Interim
Recovery
Mode will be
enabled if
configured for
fault
tolerance.
1790-Disk 0
Configuration
Error
1791-Disk 1
Error
Continued
Audible
Beeps
Error Code
L=Long
S=Short
None
None
None
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Probable Source of
Problem
Cable or hard drive
failure.
Hard drive error or
wrong drive type.
Hard drive error or
wrong drive type.
Action
1. Check the cable
connections.
2. If cables are
connected, replace
the drive.
3. If you do not want to
replace the drives
now, press F2.
Run the System
Configuration Utility and
Diagnostics and
correct.
Run the System
Configuration Utility and
Diagnostics and
correct.
3-23