3-60 Diagnostic Tools
DAAD Diagnostic Messages
Controller
restarted with a
signature of zero
DAAD recorded
errors attempting
to access: X
Disable command
issued
Drive (bay) X
needs replacing
(DAAD Error 102)
Drive Monitoring
features are
unobtainable
Drive Monitoring is
NOT enabled for
drive bay X
Drive time-out
occurred on
physical drive bay
X
Drive (bay) X
firmware needs
Message
DAAD did not find a valid
configuration signature to use
to get the data. Nonvolatile
RAM may not be present
(unconfigured) or the
signature present in
nonvolatile RAM may not
match the signature on the
controller.
DAAD found errors while
attempting to access physical
drive X, believed to be
operational. Message
followed by specific
information about the error.
Posted writes have been
disabled by the issuing of the
Accelerator Disable
command. This occurred
because of an operating
system device driver.
The 210-megabyte hard drive
has firmware version 2.30 or
2.31.
DAAD unable to get monitor
and performance data due
to fatal command problem
such as drive time-out, or
unable to get data due to
these features not supported
on the controller.
The monitor and performance
features have not been
enabled.
DAAD issued a command to a
physical drive and the
command was never
acknowledged.
Firmware on this physical drive
is below the latest
Continued
Description
Recommended Action
Run the System
Configuration Utility to
configure the controller and
nonvolatile RAM.
Replace the drive, or
correct the condition that
caused the error.
Restart the system. Run the
System Configuration Utility
to reinitialize the array
accelerator board.
Replace the drive.
Check for other errors (time-
outs, etc.). If no other errors
occur, upgrade the
firmware to a version that
supports monitor and
performance, if desired.
Run the System
Configuration Utility to
initialize the monitor and
performance features.
The drive or cable may be
bad. Check the other error
messages on the
Diagnostics screen to
determine resolution.
Run the Options ROMPaq
Utility to upgrade the drive