3-14 Diagnostic Tools
POST Error Messages
1703-SCSI
cable error
detected.
Internal SCSI
cable not
attached to
system board
connector.
System halted.
1704-
Unsupported
Virtual Mode
Disk Operation.
DOS Driver
Required.
System halted.
1705-Locked
SCSI Bus
Detected.
System halted.
1730-Fixed Disk
0 does not
support DMA
Mode.
1731-Fixed Disk
1 does not
support DMA
Mode.
1740-Fixed Disk
0 failed Set
Block Mode
command
1741-Fixed Disk
1 failed Set
Block Mode
command
Continued
Audible
Beeps
Error Code
L=Long
S=Short
None
None
None
None
None
None
None
Probable Source of
Problem
Incorrect cabling.
System attempted to
perform a virtual
mode disk operation
without virtual mode
memory services.
SCSI bus failure.
Fixed disk drive error.
Fixed disk drive error.
Fixed disk drive error.
Fixed disk drive error.
Action
Ensure that the
integrated SCSI
controller has SCSI
termination attached.
Use fixed-disk device
driver that supports
virtual mode memory
services.
Run Diagnostics.
Replace failed
assembly as indicated.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.