Compaq 1600R - ProLiant - 128 MB RAM Maintenance And Service Manual page 73

Compaq proliant 1600 and proliant 1200 servers maintenance and service guide
Hide thumbs Also See for 1600R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
1774-Slot x
Drive Array -
Obsolete data
found in Array
Accelerator.
Select F1 to
discard
contents of
Array
Accelerator.
Select F2 to
write contents
of Array
Accelerator to
drives.
1776-Drive
Array - SCSI
Port
Termination
Error
None
SMART-2 Controller
error
None
External and internal
SCSI drives are both
configured to Port 1.
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Data found in Array
Accelerator is older
than data found on
drives. Press F1 to
discard the older data
in the Array Accelerator
and retain the newer
data on the drives.
Reconfigure drives.
Continued
3-19