Critical Error Log Messages
NMI - PCI Bus Parity
Error
NMI - Expansion
Board Error
NMI - Expansion Bus
Master Time-Out
NMI - Expansion Bus
Slave Time-Out
NMI - Fail-Safe Timer
Expiration
Processor Exception The indicated processor exception occurred.
NMI - Processor
Parity Error
Server Manager
Failure
NMI - Software
Generated Interrupt
Detected Error
Caution:
Temperature
Exceeded
Abnormal Program
Termination
ASR-2 Test Event
NMI- Automatic
Server Recovery
Timer Expiration
Required System
Fan Failure
UPS A/C Line Failure
Shutdown or Battery
Low
ASR-2 detected by
ROM
Message
A parity error was detected on the PCI bus.
A board on the expansion bus indicated an error condition,
resulting in a server failure.
A bus master expansion board in the indicated slot did not
release the bus after its maximum time, resulting in a server
failure.
A board on the expansion bus delayed a bus cycle beyond
the maximum time, resulting in a server failure.
Software was unable to reset the system fail-safe timer,
resulting in a server failure.
The processor detected a data error, resulting in a server
failure.
An error occurred with the Server Manager/R.
Software indicated a system error, resulting in a server failure.
The operating system has detected that the temperature of
the system has exceeded the caution level. Accompanying
data in the log notes if an auto-shutdown sequence has been
invoked by the operating system.
The operating system has encountered an abnormal situation
that has caused a system failure.
The System Configuration Utility generated a test alert.
The operating system has received notice of an impending
ASR-2 timer expiration.
The required system fan has failed. Accompanying data in the
log notes if an auto-shutdown sequence has been invoked by
the operating system.
The UPS notified the operating system that the AC power line
has failed. Accompanying data indicates if an auto-shutdown
sequence has been invoked or if the battery has been nearly
depleted.
An ASR-2 activity has been detected and logged by the
system ROM.
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide