3-16 Diagnostic Tools
POST Error Messages
1764-Slot x Drive Array - Capacity Expansion Process is
temporarily disabled (followed by one of the following):
Expansion will resume when Array Accelerator has been
reattached.
Expansion will resume when Array Accelerator has been
replaced.
Expansion will resume when Array Accelerator RAM
allocation is successful.
Expansion will resume when Array Accelerator battery
reaches full charge.
Expansion will resume when automatic data recovery
has been completed.
1765-Slot x Drive Array Option ROM Appears to Conflict
With an ISA Card. ISA cards with 16-bit memory cannot
be configured in memory range C0000 to DFFFF along
with the SMART-2/E 8-bit Option ROM due to EISA bus
limitations. Please remove or reconfigure your ISA card.
1766-Slot x Drive Array requires System ROM Upgrade.
Run Systems ROMPaq Utility.
1767-Slot x Drive Array Option ROM is Not Programmed
Correctly or may Conflict with the Memory Address
Range of an ISA Card. Check the Memory Address
Configuration of installed ISA Card(s) or run Options
ROMPaq Utility to attempt SMART-2/E Option ROM
Reprogramming.
1768-Slot x
Drive Array -
Resuming
logical drive
expansion
process.
Continued
Audible
Beeps
Error Code
L=Long
S=Short
None
Probable Source of
Problem
SMART-2 Controller
error.
Action
Reattach or replace
Array Accelerator, wait
until the Array
Accelerator batteries
have charged, or for
Automatic Data
Recovery to complete,
as indicated.
Remove or reconfigure
conflicting ISA cards.
Disable " shared
memory" on any ISA
network cards that may
be installed.
Run the latest Systems
ROMPaq Utility to
upgrade your System
ROMs.
Remove or reconfigure
conflicting ISA cards,
especially any cards
that are not recognized
by the System
Configuration Utility. Try
reprogramming the
SMART-2/E Controller's
ROMs using the latest
Options ROMPaq
(version 2.29 or higher).
No action required.
Appears whenever a
controller reset or
power cycle occurs
while array expansion is
in progress.

Advertisement