adapter resources
Less than 75%
batteries at
sufficient voltage
sufficient resources to perform
operations to the array
accelerator board. Drive
rebuild may be occurring.
The operation of the array
accelerator board has been
disabled due to less than 75%
of the battery packs being at
the sufficient voltage level.
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
the array accelerator board
until the drive rebuild
completes.
Allow sufficient time for the
batteries to recharge (36
hours). If the batteries have
not recharged after 36
hours, replace the array
accelerator board.
Continued
3-63