3-80 Diagnostic Tools
The following ASR-2 flow chart shows you the sequence of events after a hardware or
software error occurs:
If the server continues experiencing
hardware/software errors and the
number of ASR cycles exceed the
specified number of recovery
attempts, the server will log an error
to the Server Health Log or the
Integrated Management Log and
boot the Compaq Utilities from the
system partition on the hard drive
Figure 3-1. ASR-2 Flow Chart
Error records in the Server Health Log or
Operating System halts normal operation
is enabled, the Server Failure Notification
|
Unattended server boots the
Operating System
Hardware/Software error occurs
|
in the Integrated Management Log,
depending on the server
|
|
ASR Timer expires
|
Server is reset
|
If a modem is installed and paging
pager alert is sent to
the Server Administrator
---Or---
on the system partition on the hard
the modem on auto answer so that
the Server Administrator can dial in
using third party terminal emulator
console to identify the source of the
Server boots the Compaq Utilities
drive
|
If a modem is installed, ASR puts
software to remotely run the
Compaq Utilities to identify the
source of the fault
|
Or
|
Local Server Administrator runs
Compaq Utilities from server
fault