Compaq 1600R - ProLiant - 128 MB RAM Maintenance And Service Manual page 139

Compaq proliant 1600 and proliant 1200 servers maintenance and service guide
Hide thumbs Also See for 1600R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
Network
IP net
mask
Network
IP router
address
If you configure the server to boot into Compaq Utilities, it prepares for remote
communications. You can remotely run Diagnostics software, Inspect Utility, or System
Configuration Utility using a workstation running terminal emulation software, such as
Compaq Insight Manager or PC Anywhere.
Booting into the Operating System
When you enable ASR-2 to restart into the operating system and a critical error occurs,
ASR-2 logs the error in the Critical Error Log and restarts the server. The system ROM
pages the designated administrator, and executes the normal restart process.
IMPORTANT: When you enable ASR-2 to restart into the operating
system, Modem Dial-In Status, Network Status, and Modem Dial-Out
Status are automatically disabled. In this mode, ASR-2 can page
you if a critical error occurs, but you cannot access the server, and
the server cannot dial out to a remote workstation.
During the recovery process, the ASR-2 feature tries to restart the server up to 10 times. If
the ASR-2 feature cannot restart the server within 10 attempts, it logs a critical error in the
Critical Error Log, restarts the server into the Compaq Utilities, and puts the modem into
auto-answer mode.
Your System Configuration Utility setting should resemble the following when you enable
ASR to restart into the operating system:
Serial interface
Dial-in status
Dial-out status
Dial-out string
Network status
Network protocol
Network controller
Network host name
Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide
Enter the net mask for this server in standard dot
notation.
NOTE: This is not used if you select Custom for network
controller. You must enter your IP address in the NET.
CFG file that you load into the system partition.
Enter the router to be used for this server in standard dot
notation.
NOTE: This is not used if you select Custom for network
controller. You must enter your IP address in the NET.
CFG file that you load into the system partition.
COM1
Disabled
Disabled
555-1234
Disabled
IPX
Compaq
CPQHOU
3-85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant 1200Proliant 1600