3-56 Diagnostic Tools
DAAD Diagnostic Messages
Accelerator
status: Valid
data found at
reset
Accelerator
status: Warranty
alert
Adapter/NVRAM
ID mismatch
Battery pack X
below reference
voltage
Battery X not
fully charged
Board not
attached
NVRAM
configuration
present,
controller not
detected
Compatibility
port problem
detected
Configuration
Message
Valid data was found in posted
write memory at reinitialization.
Data will be flushed to disk.
Catastrophic problem with
array accelerator board. Refer
to other messages on
Diagnostics screen for exact
meaning of this message.
EISA nonvolatile RAM has an ID
for a different controller from
the one physically present in
the slot.
Battery pack on the array
accelerator is below the
required voltage levels.
Battery is not fully charged.
Array controller configured for
use with array accelerator
board, but one is not attached.
EISA nonvolatile RAM has a
configuration for an array
controller but there is no board
in this slot. Either a board has
been removed from the system
or a board has been placed in
the wrong slot.
Compatibility port configured
for this IDA controller. When
DAAD was verifying this
interface, a serious problem
was detected.
DAAD detected that
Continued
Description
Recommended Action
Not an error or data loss
condition. No action needs
to be taken.
Replace the array
accelerator board.
Run the System
Configuration Utility.
Allow enough time for
batteries to recharge (36
hours). If batteries have not
recharged after 36 hours,
replace the array
accelerator board.
If 75% of the batteries
present are fully charged,
the array accelerator is fully
operational. If more than
75% of the batteries are not
fully charged, allow 36 hours
to recharge them.
Attach array accelerator
board to array controller.
Place the array controller in
the proper slot or run the
System Configuration Utility
to reconfigure nonvolatile
RAM to reflect the removal
or new position.
A hardware problem has
occurred; replace the IDA
controller.
Run the latest version of