Compaq 1600R - ProLiant - 128 MB RAM Maintenance And Service Manual page 116

Compaq proliant 1600 and proliant 1200 servers maintenance and service guide
Hide thumbs Also See for 1600R - ProLiant - 128 MB RAM:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
3-62 Diagnostic Tools
DAAD Diagnostic Messages
Drive (bay) X RIS
copy mismatch
Drive (bay) X
upload code not
readable
Duplicate write
memory error
Error occurred
reading RIS copy
from drive (bay) X
FYI: Drive (bay) X is
non-Compaq
supplied
Identify controller
data did not
match with
NVRAM
Identify logical
drive data did not
match with
NVRAM
Insufficient
Message
The copies of the RIS on this
drive do not match.
An error occurred while DAAD
was trying to read the upload
code information from this
drive.
Data could not be written to
the array accelerator board in
duplicate due to the
detection of parity errors. This
is not a data loss situation.
An error occurred while DAAD
was trying to read the RIS from
this drive.
The installed drive was not
supplied by Compaq.
The identify controller data
from the array controller did
not match with the
information stored in
nonvolatile RAM. This could
occur if new, previously
configured drives have been
placed in a system that has
also been previously
configured. It could also
occur if the firmware on the
controller has been upgraded
and the System Configuration
Utility was not run.
The identify unit data from the
array controller did not match
with the information stored in
nonvolatile RAM. This could
occur if new, previously
configured drives have been
placed in a system that has
also been previously
configured.
The adapter does not have
Continued
Description
Recommended Action
This drive may need to be
replaced. Check for other
errors.
If there were multiple errors,
this drive may need to be
replaced.
Replace the array
accelerator board.
If there were multiple errors,
this drive may need to be
replaced.
If problems exist with this
drive, replace it with a
Compaq drive.
Check the identify
controller data under the
Inspect Utility. If the
firmware version field is the
only thing different
between the controller and
nonvolatile RAM data, this is
not a problem. Otherwise
run the System
Configuration Utility.
Run the System
Configuration Utility to
configure the controller and
nonvolatile RAM.
Operate the system without