3-64 Diagnostic Tools
DAAD Diagnostic Messages
Logical drive X
failed due to
cache error
Logical Drive X
status = FAILED
Logical Drive X
status = INTERIM
RECOVERY
Logical Drive X
status = LOOSE
CABLE DETECTED
Logical Drive X
status = NEEDS
RECOVER
Logical Drive X
status =
OVERHEATED
Logical Drive X
status =
Message
This logical drive failed due to
a catastrophic cache error.
This status could be issued for
several reasons. If this logical
drive is configured for No Fault
Tolerance and one or more
drives fail, this status will occur.
If mirroring is enabled, and
any two mirrored drives fail,
this status will occur. If Data
Guarding is enabled, and two
or more drives fail in this unit,
this status will occur. This status
may also occur if another
configured logical drive is in
the WRONG DRIVE REPLACED
or LOOSE CABLE DETECTED
state.
A physical drive in this logical
drive has failed. The logical
drive is operating in interim
recovery mode and is
vulnerable.
A physical drive has a cabling
problem.
A physical drive in this logical
drive has failed and has now
been replaced. This drive
needs to be rebuilt from the
mirror drive or the parity data.
The temperature of the
Intelligent Array Expansion
System drives is beyond safe
operating levels and it has
shut down to avoid damage.
The temperature of the
Intelligent Array Expansion
Continued
Description
Recommended Action
Replace the array
accelerator board and
reconfigure using the
System Configuration Utility.
Check for drive failures,
wrong drive replaced, or
loose cable messages. If
there was a drive failure,
replace the failed drive(s)
and then restore the data
for this logical drive from the
tape backup. Otherwise,
follow the wrong drive
replaced or loose cable
detected procedures.
Replace the failed drive as
soon as possible.
Turn the system off and
attempt to reattach the
cable onto the drive. If this
does not work, replace the
cable.
When booting up the
system, select the "F1 -
rebuild drive" option to
rebuild the replaced drive.
Check the fans and the
operating environment.
Check the fans and the
operating environment.