3-68 Diagnostic Tools
DAAD Diagnostic Messages
Drive (bay) X is a
replacement drive
marked OK
Drive (bay) X is
failed
Drive (bay) X has
insufficient
capacity for its
configuration
Drive (bay) X is
undergoing drive
recovery
Drive (bay) X was
inadvertently
replaced
SCSI port X, drive
ID Y firmware
needs upgrading
Set configuration
command issued
Soft Firmware
Upgrade required
Message
This drive has been replaced
and marked OK by the
firmware. This may occur if a
drive has an intermittent
failure (for example, if a drive
has previously failed, then
when DAAD is run, the drive
starts working again).
The indicated physical drive
has failed.
Drive has insufficient capacity
to be used in this logical drive
configuration.
This drive is being rebuilt from
the corresponding mirror or
parity data.
The physical drive was
incorrectly replaced after
another drive failed.
Drive's firmware may cause
problems and should be
upgraded.
The configuration of the array
controller has been updated.
The array accelerator board
may remain disabled until it is
reinitialized.
DAAD has determined that
your controller is running
firmware that has been soft
upgraded by the Compaq
Upgrade Utility. However, the
firmware running is not
present on all drives. This
could be caused by the
addition of new drives in the
system.
Continued
Description
Recommended Action
Replace the drive.
Replace this drive.
Replace this drive with a
larger capacity drive.
Normal operations should
occur.
Replace the drive that was
incorrectly replaced and
replace the original drive
that failed. Do not run the
System Configuration Utility
and try to reconfigure; data
will be lost.
Run Options ROMPaq to
upgrade the drive's
firmware to a later revision.
Run the System
Configuration Utility to
reinitialize the array
accelerator board.
Run the Compaq Upgrade
Utility to place the latest
firmware on all drives.