Dell PowerEdge E06S Series Hardware Owner's Manual page 54

Dell server hardware owner's manual
Table of Contents

Advertisement

Message
PCIe Training
Error: Expected
Link Width is x ,
Actual Link Width
is y .
Plug & Play
Configuration
Error.
Read fault
Requested sector
not found.
SATA Port x device
not found.
54
About Your System
Causes
Faulty or improperly installed
PCIe card in the specified
slot.
Error encountered in
initializing PCIe device;
faulty system board.
The operating system cannot
read from the hard drive,
optical drive, or USB device,
the system could not find a
particular sector on the disk,
or the requested sector is
defective.
There is no device connected
to the specified SATA port.
Corrective Actions
Reseat the PCIe card in the
specified slot number. See
"Troubleshooting Expansion
Cards" on page 189. If the
problem persists, see
"Getting Help" on page 203.
Install the NVRAM_CLR
jumper in the clear position
(pins 1 and 3) and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards" on page 189.
Replace the optical medium,
USB medium or device.
Ensure that the SAS
backplane, USB, or SATA
cables are properly
connected. See
"Troubleshooting a USB
Device" on page 174,
"Troubleshooting an Optical
Drive" on page 185, or
"Troubleshooting a Hard
Drive" on page 186 for the
appropriate drive(s) installed
in your system.
Information only.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e06s001Poweredge r910External oemr r910

Table of Contents