Dell PowerEdge E06S Series Hardware Owner's Manual page 30

Dell server hardware owner's manual
Table of Contents

Advertisement

Code
Text
E1618 Predictive
failure on
Power Supply
# (### W).
Check PSU.
E161C Power Supply
# (### W)
lost AC
power. Check
PSU cables.
E1620 Power Supply
# (### W) AC
power error.
Check PSU
cables.
E1624 Lost power
supply
redundancy.
Check PSU
cables.
E1626 Power Supply
Mismatch.
PSU1 = ### W,
PSU2 = ### W.
E1629 Power
required >
PSU wattage.
Check PSU and
config.
30
About Your System
Causes
A power supply fan failure,
an over-temperature
condition, or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
Specified power supply is
attached to the system, but
it has lost its AC input.
Specified power supply's AC
input is outside of the
allowable range.
The power supply subsystem
is no longer redundant. If
the remaining power supply
fails, the system will shut
down.
The power supplies in the
system are not the same
wattage.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
Corrective Actions
See "Troubleshooting
Power Supplies" on
page 179.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 179.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 179.
See "Troubleshooting
Power Supplies" on
page 179.
Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system's Getting
Started Guide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e06s001Poweredge r910External oemr r910

Table of Contents