Dell PowerEdge E06S Series Hardware Owner's Manual page 202

Dell server hardware owner's manual
Table of Contents

Advertisement

3 Remove the jumper plug from the password jumper.
See Figure 6-1 to locate the password jumper (labeled "PWRD_EN") on
the system board.
4 Close the system.
5 Reconnect your system and peripherals to their electrical outlets, and turn
on the system.
The existing passwords are not disabled (erased) until the system boots
with the password jumper plug removed. However, before you assign a new
system and/or setup password, you must install the jumper plug.
NOTE:
still removed, the system disables the new password(s) the next time it boots.
6 Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
7 Open the system. See "Closing the System" on page 90.
8 Install the jumper plug on the password jumper.
9 Lower the memory module shroud.
10 Close the system.
11 Reconnect your system and peripherals to their electrical outlets, and turn
on the system.
12 Assign a new system and/or setup password.
To assign a new password using the System Setup program, see "Assigning
a System Password" on page 79.