Troubleshooting A Storage Controller - Dell PowerEdge E06S Series Hardware Owner's Manual

Dell server hardware owner's manual
Table of Contents

Advertisement

2 If applicable, remove the bezel. See "Removing the Front Bezel" on
page 87.
3 If your system has a RAID controller and your hard drives are configured in
a RAID array, perform the following steps.
Restart the system and enter the host adapter configuration utility
a
program by pressing <Ctrl><R> for a PERC controller or
<Ctrl><C> for a SAS controller.
See the documentation supplied with the host adapter for information
about the configuration utility.
Ensure that the hard drive(s) have been configured correctly for the
b
RAID array.
Take the hard drive offline and reseat the drive. See "Removing a Hard
c
Drive" on page 109.
Exit the configuration utility and allow the system to boot to the
d
operating system.
4 Ensure that the required device drivers for your controller card are installed
and are configured correctly. See the operating system documentation for
more information.
5 Restart the system, enter the System Setup program, and verify that the
controller is enabled and the drives appear in the System Setup program.
See "Using the System Setup Program and UEFI Boot Manager" on
page 63.
If the problem persists, see "Troubleshooting a Storage Controller" on
page 187.

Troubleshooting a Storage Controller

NOTE:
When troubleshooting a SAS or PERC controller, also see the
documentation for your operating system and the controller.
1 Run the appropriate online diagnostic test. See "Using Online Diagnostics"
on page 193.
2 Enter the System Setup program and ensure that the SAS or PERC
controller is enabled. See "Using the System Setup Program and UEFI
Boot Manager" on page 63.
Troubleshooting Your System
187

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e06s001Poweredge r910External oemr r910

Table of Contents