Code
Text
E1313 Fan
redundancy
lost. Check
fans.
E1314 Critical
system
cooling loss.
Check fans.
E1410 System Fatal
Error
detected.
E1414 CPU # temp
exceeding
range. Check
CPU heatsink.
E1418 CPU # not
detected.
Check CPU is
seated
properly.
E141C Unsupported
CPU configur-
ation. Check
CPU or BIOS
revision.
28
About Your System
Causes
The system is no longer fan
redundant. Another fan
failure would put the system
at risk of over-heating.
All fans have been removed
from system.
A fatal system error has been
detected.
Specified processor is out of
acceptable temperature
range.
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
Processors are in an
unsupported configuration.
Corrective Actions
Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan"
on page 180.
Ensure that the fans are
properly installed. See
"Troubleshooting a Fan"
on page 180.
Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processors" on page 190
and "Troubleshooting
System Cooling
Problems" on page 180.
Ensure that the specified
processor is properly
installed. See
"Troubleshooting the
Processors" on page 190.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system's
Getting Started Guide.