Kodak HR User Manual page 94

Table of Contents

Advertisement

Using the Long Roll Accessory
D-30
6. If the marked frame is not aligned with the right edge of the aperture plate,
select View>Configurations.
a. If the film is moving from left to right, change the Left Sensor Offset:
If the center of the frame is beyond the right edge of the aperture plate,
decrease the Left Sensor Offset.
If the center of the frame has not reached the right edge of the aperture
plate, increase the Left Sensor Offset.
b. If the film is moving from right to left, change the Right Sensor Offset:
If the center of the frame is beyond the left edge of the aperture plate,
decrease the Right Sensor Offset.
If the center of the frame has not reached the left edge of the aperture
plate, increase the Right Sensor Offset.
7. On the View Controls window, click Next Frame.
8. Repeat steps 1 through 7 until the center of the frame lines up exactly with the
right edge of the aperture plate.
9. On the View Controls window, click Fast Fwrd>> to advance the roll of film to
the right side.
10. Repeat Locating the First Punched Frame (see page D-26) and Checking the
Alignment and Adjusting the Sensor Offsets (see page D-28) for the right
sensor.
May 2002