Setting the Scan Parameters
May 2002
1. Select Test>Long Roll Capture from the SAM menu.
2. Set the Scan and Positioning Info.
a. Set the #Lines (dy) to 1.
b. Set the Line Offset (y) to 0.
c. Set Pixel Summing to None.
d. Keep the default values for #Pixels (dx), Pixel Offset (x) and X Offset.
IMPORTANT: Make sure you close the Test Long Roll Capture window in the
next step.
3. Close the Test Long Roll Capture window.
Using the Long Roll Accessory
D-25