GRT1-PRT Configuration

External Dimensions (mm)
1-3

GRT1-PRT Configuration

PROFIBUS Configuration
Means
GRT1-PRT Configuration
DTM
23.1
24.4
61.2
1.5
The PROFIBUS DP Master Unit requires a configuration before it can
exchange I/O data with any of its slave devices. For this configuration infor-
mation on the slave device must be available. OMRON provides two means
to facilitate Master Unit configuration.
• A GRT1-PRT DTM
• A GRT1-PRT GSD file
The GRT1-PRT DTM is an executable component, provided by OMRON,
which requires an FDT Container program like OMRON's Cx-Profibus (refer
also to Appendix A-9 FDT/DTM Technology). The DTM runs inside this FDT
Container and provides its own User Interfaces. It can access GRT1-PRT and
SmartSlice I/O Unit data through the PROFIBUS Master unit and present that
to the user. It can also save the settings, using the features of the FDT Con-
tainer program.
The GRT1-PRT DTM, provides the user with the following features.
• Parameter configuration
• I/O Configuration
• Configuration of individual SmartSlice I/O Units
• Monitoring of the SmartSlice I/O System
Note In order to configure individual SmartSlice I/O Units, the PROFIBUS Master
Unit must support PROFIBUS DP-V1, Class 2 functionality. The OMRON
CS1/CJ1W-PRM21 PROFIBUS Master Units support this functionality as of
revision 3.
69.7
Section 1-3
OMRON
GRT1-PRT
RUN
RUN
UNIT PWR
UNIT PWR
5
5
ERR
ERR
0
0
BF BF
X10
X10
X1
X1
TS TS
I/O PWR
I/O PWR
ON
ON
BUS
BUS
1
REGS
REGS
2
NC
NC
3
ADR
ADR
4
BACK
BACK
UNIT
UNIT
+V +V
-V
+V +V
-V -V
DC24V
DC24V
INPUT
INPUT
17.1
36.8
58
2.4
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profibus - 27-11-2006Smartslice grt1-seriesGrt1-prt

Table of Contents