YPP6830 Explosion-Proof Pulse Input Rate/Totalizer

Reset Meter to Factory Defaults

Reset to factory defaults will restore most meter
parameters to their factory default setting.
When the parameters have been changed in a way
that is difficult to determine what's happening, it might
be better to start the setup process from the factory
defaults.
Factory default reset does not change the saved
backup restore settings, override passwords, or edit
parameters locked by a permanent non-resettable
grand total. See Non-Resettable Grand Total, as
described on page 41.
Instructions to load factory defaults can be found in
the Backup & Restore (BACKUP) menu on page 44.
Factory Defaults & User
Settings
The following table shows the factory setting for most
of the programmable parameters on the meter. Next
to the factory setting, the user may record the new
setting for the particular application.
Model: _________________________
S/N: ___________________________
Date: __________________________
Parameter
Display
INPUT
Input Type
K-Factor
FuNiT
units
Factr
K-Factor
Tbase
Rate Time
Base
RateU
Rate Unit
Tot U
Total Unit
Nmult
Total
Multiplier
GtotU
Grand Total
Unit
Nmult
Grand Total
Multiplier
1111. 1
Rate
Decimal
Point
111111. 1
Total
Decimal
Point
111111. 1
Grand Total
Decimal
Point
Total
Conversion
TotCF
Factor
Grand Total
Conversion
grtCF
Factor
Top Display
TOP
Bottom
BOTNm
Display
Advanced Features
Default
User
Setting
Setting
Active
Pulses/
Gallon
1.0000
Second
Gallons/
second
Gallons
x1
Gallons
x1
1 place
1 place
1 place
N/A (Only
valid with
custom
units)
N/A (Only
valid with
custom
units)
Rate
Total
Parameter
Display
Total Reset
T rst
Grand Total
T rst
Reset
Analog Out
A out
Value
Output
Dspl1
Display 1
Out 1
Output 1
Output
Dspl2
Display 2
Output 2
Out 2
Scale
SCALE
Enable
Scale/Cal #
nopts
Points
Funit
Scale Unit
Scale Unit
time
Time Base
Scale/Cal
Inpt1
Input 1
Scale/Cal
dspl1
Display 1
Scale/Cal
Inpt2
Input 2
Scale/Cal
Dspl2
Display 1
Parameter
Lock
PASS
Password
Total Reset
PASS T
Password
Grand Total
Reset
PASS GT
Password
Output 1
OUT 1
Output 2
OUT 2
LO GATE
Low Gate
HI GATE
High Gate
FILTER
Filter
CUTOFF
Cutoff
Battery
BaT SYM
Symbol
Modbus
sLvID
Slave ID
Baud Rate
baud
Time Delay
Tdely
Party
Parity
Additional Parameters & Notes
49
Instruction Manual
Default
User
Setting
Setting
Manual -
Enabled
Manual -
Enabled
Rate
0000.0
4.000
1000.0
20.000
No – Use
K-Factor
2 (N/A)
Pulses/Gall
on (N/A)
Second
(N/A)
00000 (N/A)
0000.0
(N/A)
1000 (N/A)
1000.0
(N/A)
00000
(unlocked)
00000
(unlocked)
00000
(unlocked)
Off
Off
1
2
High Speed
0 (disabled)
Disabled
247
9,600 bps
10 ms
Even

Advertisement

Table of Contents
loading

Table of Contents