Open Collector Outputs (Output) - YOKOGAWA YPP6830-AP0-0 Instruction Manual

Explosion-proof pulse input rate/totalizer
Table of Contents

Advertisement

YPP6830 Explosion-Proof Pulse Input Rate/Totalizer
Display
Parameter
TIME
Time
DATALOG
Data log
LOGTIME
Log time
LOG 1
Log 1
DsAbL
Disable
INTERVL
Interval
STArT
Start
LOGVIEW
Log view
ALL
All log view
LOGVIEW
LOG NUM
Log number
ALL
All erase
ERASE
Erase?
Erase?
BAKLITE
Backlight
DsabL
Disable
EnAbL
Enable
AO CAL
Analog output
calibration
BACKUP
Backup
SAvE?
Save?
LOad?
Load?
DEFLT
Default
RESET
Reset defaults
DFALTS?
Bat syM
Battery symbol
DsabL
Disable
EnAbL
Enable
INFO
Info
SOFT
Software
ver
Version
nmodL
Model
COMM
Communications
mbus
Modbus
SlvID
Slave ID
BaUd
Baud rate
Tdely
Transmit delay
Party
Parity
STANDBY
Standby
Yes?
Yes
Action/Setting
Set the hour and
minute
Enter Data Log menu
Set daily data log
times
Set first daily log time
(1-4)
Disable log number
Set interval log time
Begin interval logging
View data log
View all data log
points
Go to specific log
number
Erase all logs
Confirm to erase all
logs
Enable or disable
backlight
Disable backlight
Enable backlight
Enter Analog Output
Calibration menu
Enter Backup menu
Save current
parameters to backup
restore
Load parameters from
backup restore
Restore factory default
parameter settings
Confirm factory reset
Enter Battery Symbol
menu
Disable battery symbol
Enable battery symbol
Enter Info menu
Display software ID
number
Display software
version number
Display model number
Enter Communications
menu
Enter Modbus
communications menu
Set Modbus slave ID
Set baud rate
Set transmit delay
time
Set parity and stop
bits
Enter standby mode
(battery powered only)
Confirm standby mode
31

Open Collector Outputs (OUTPUT)

The meter is equipped with two NPN open collector
outputs that may be set up for pulse outputs, alarms,
timed pulses, or turned off.
Pulse outputs are based on rate, total or grand total
counts, or one-for-one retransmit for input pulses.
Both outputs may be used to generate a quadrature
output based on any output type. An output test
mode can be used to generate pulses at a constant
programmable frequency.
Alarms are available based on the rate, total, or grand
total. The alarm status will show on the display even if
the output is not wired. The outputs may also be
forced on or off.
A timed pulse output generates constant pulses at a
specified frequency and on time.
A total reset output generates a pulse whenever the
selected total or grand total is reset, regardless of the
reset method used. The On time is programmable
between 0.10 and 99,999.99 sec.
The output may be disabled by selecting Off.
Instruction Manual