YOKOGAWA YPP6830-AP0-0 Instruction Manual page 30

Explosion-proof pulse input rate/totalizer
Table of Contents

Advertisement

YPP6830 Explosion-Proof Pulse Input Rate/Totalizer
Display
Parameter
total
Total output
Grtot
Grand total
output
Dsp 1
Display 1
OUt 1
Output 1
Dsp 2
Display 2
OUt 2
Output 2
Save?
Save
dsabl
Disable
GATE
Gate
LO
Low gate
HI
High gate
FILTER
Filter
HI
High speed filter
nmed
Medium speed
filter
LO
Low speed filter
CUTOFF
Low-flow
cutoff
SCALCAL
Scale &
calibrate
sCalE
Scale
Cal
Calibrate
Undo?
Undo K-factor
KFACTOR
Undo?
Undo scaling &
SCALCAL
calibration
No?
No
Yes?
Yes
Nopts
Number of
points
Inp 1
Input 1
Dsp 1
Display 1
Inp 2
Input 2
DsP 2
Display 2
Save?
Save
T RESET
Total reset
T rST
Total reset
man
Manual
Enabl
Enable
dsabl
Disable
Auto
Automatic
Action/Setting
Set total as output
variable
Set grand total as
output variable
Output display 1 value
Output 1 value
Output display 2 value
Output 2 value
Save entered analog
parameters
Turn off the analog
output
Enter Gate menu
Set Low Gate
Set High Gate
Enter Filter menu
Set high speed filter
Set medium speed
filter
Set low speed filter
Enter Low-Low Cutoff
menu
Enter the Scale &
Calibrate menu to
program without using
a K-Factor
Enter the Scale menu
Enter the Calibrate
menu
Undo the K-Factor
input programming
Undo the scaling and
calibration input
programming
Do not undo other
programming
Undo other
programming
Enter the number of
scaling or calibration
points
Calibrate or scale input
1 value
Program display 1
value
Calibrate or scale input
2 value
Program display 2
value
Save entered
calibration or scale
parameters
Enter the Total Reset
menu
Select the Total Reset
method
Manual total reset
Enable manual reset
Disable manual reset
Automatic total reset
30
Display
Parameter
T DELAY
Time delay
time
Total Reset
Time
Set
Set Clock
CLOCK
GTrST
Grand total reset
PASSWRD
Password
Pass
Password
Pass T
Password total
Pass GT
Password grand
total
UnLOC
Unlock
LOCd
Lock
UNLOCKD
Unlocked
LOCKED
Locked
CUSTOM
Custom
POS 1
Position 1
POS 8
Position 8
SYSTEM
System
SETTIME
Set time
YEAR
Year
MONTH
Month
01
January
02
February
03
March
04
April
05
May
06
June
07
July
08
August
09
September
10
October
11
November
12
December
DAY
Day
Instruction Manual
Action/Setting
Automatic reset time
delay
Note: This setting is
activated when the
total reaches an
output set point, it can
be used for simple
batch operations.
Enter the time of day
to reset the total
hh.mm (Default: 00.00
midnight)
Message indicates
that the clock must be
set. Go to Advance –
System – Set Time
Select the Grand Total
Reset method
Enter the Password
menu
Program password to
lock meter parameters
Program password to
prevent total reset
Enter password to
permanently lock out
grand total related
parameters and reset
Password has been
unlocked
Password has been
locked
Program password to
lock meter
Enter password to
unlock meter
Enter Custom menu
Set menu position 1
(1-8)
Set menu position 8
Enter System menu
Set real-time clock
date and time
Set the year
Set the month
Set month as January
Set month as
February
Set month as March
Set month as April
Set month as May
Set month as June
Set month as July
Set month as August
Set month as
September
Set month as October
Set month as
November
Set month as
December
Set the day