YPP6830 Explosion-Proof Pulse Input Rate/Totalizer

Product Ratings and Approvals

FM
Explosion-proof for use in:
Class I, Division 1, Groups B, C and D
Dust-ignition proof for use in:
Class II/III, Division 1, Groups E, F and G; T6
Flame-proof for use in:
Class I, Zone 1, AEx d Group IIC; T6
Protection by Enclosure:
Zone 21, AEx tb IIIC; T85°C
Ta = -40 to 75°C.
Enclosure: Type 4X, IP66.
Certificate number: 3040391
CSA
Explosion-proof for use in:
Class I, Division 1, Groups B, C and D
Dust-ignition proof for use in:
Class II/III, Division 1, Groups E, F and G; T6
Flame-proof for use in:
Zone 1, Ex d IIC T6
Ta = -40 to 75°C.
Enclosure: Type 4X & IP66/IP68.
Certificate number: 2325749
ATEX
II 2 G D. Flame-proof for use in:
Zone 1, Ex d IIC T6 Gb
Protection by Enclosure for use in:
Dust Atmospheres (Zone 21)
Ex tb IIIC T85°C Db IP68.
Ta = -40°C to +75°C
Certificate number: Sira 13ATEX1121X
IECEx
Flame-proof for use in:
Zone 1, Ex d IIC T6 Gb
Protection by Enclosure for use in:
Dust Atmospheres (Zone 21)
Ex tb IIIC T85°C Db IP68.
Ta = -40°C to +75°C
Certificate number: IECEx SIR 13.0042X
Special Conditions for Safe Use:
Use suitably certified and dimensioned cable entry device
and/or plug. The equipment shall be installed such that the
supply cable is protected from mechanical damage. The cable
shall not be subjected to tension or torque. If the cable is to be
terminated within an explosive atmosphere, then appropriate
protection of the free end of the cable shall be provided.
Year of Construction:
This information is contained within the serial number with
the first four digits representing the year and month in the
YYMM format.
For European Community:
The YPP6830 must be installed in accordance with the
ATEX directive 2014/34/EU, the product certificate Sira
13ATEX1121X, and the product manual.

Electromagnetic Compatibility

Emissions
EN 61326-1
Safety requirements for measurement,
control, and laboratory use – Industrial
Group 1 Class A ISM emissions
requirements
EN55022
Class A ITE emissions requirements
EN61000-6-4
Emissions for heavy industrial
environments - Generic
Radiated
Class A
Emissions
Immunity
EN 61326-1
Measurement, control, and laboratory
use – Industrial EN61000-6-2
Immunity for heavy environments -
Generic
ESD
±4 kV contact, ±8 kV air
RFI –
80-1000 MHz @ 10 V/m,
Amplitude
1.4-2.0 GHz @ 3 V/m,
Modulated
2.0-2.7 GHz @ 1 V/m,
80% AM (1 kHz)
EFT
±2 kV DC mains, ±1 kV other
Telco Surge
±1 kV
CRFI
3 V, 0.15-80 MHz, 1 kHz 80% AM
Power
30 A/m 70% V for 0.5 period
Frequency
Magnetic Field