YPP6830 Explosion-Proof Pulse Input Rate/Totalizer

Advanced Features Menu

To simplify the setup process, functions not needed
for most applications are located in the Advanced
Features menu. Access the Advanced features menu
by pressing Enter at the Advance menu in the Main
Menu defined on page 19.
The Advanced Features menu is used to select:
1.
Open collector output configuration (OUTPUT)
Analog output configuration (A OUT)
2.
3.
Gate function for low speed inputs (GATE)
4.
Set the input filter (FILTER)
5.
Set low flow cutoff (CUTOFF)
6.
Scale or live calibrate the meter and override
K-Factor (SCALCAL)
7.
Select method of total and grand total reset
(T RESET)
8.
Set passwords (PASSWRD)
9.
Reconfigure the Main menu structure
(CUSTOM)
10. Enter the System menu for meter settings
and data logging (SYSTEM)
11. Configure serial communication settings
(COMM) – if applicable
12. Enter low-power Standby Mode (STANDBY)
on battery powered models
Advanced menus A OUT displayed only for meters
with the analog output option, COMM displayed only for
meters with the serial communications option, and
STANDBY only for meters with battery or battery
backup power.
Press the Enter button to access any menu or press
the Up arrow button to scroll through choices. Press
the Menu button to back out of a menu, or hold the
Menu button to exit at any time.
Advanced Features Menu & Display
Messages
The following table shows the Advanced features
menu functions and messages in the order they
appear in the menu.
Display
Parameter
ADVANCE
Advanced
OUTPUT
Output
OUT 1
Output 1
OUT 2
Output 2
PuLSE
Pulse
rate
Rate
total
Total
Grtot
Grand total
dec. p t
Decimal point
count
Count
Retr
Retransmit
quad
Quadrature
Test
Test
ALrnm
Alarm
rate
Rate
Set
Set point
reset
Reset point
total
Total
Grtot
Grand total
Set
Set point
On
On
Off
Off
Tnmer
Timer
Start
Start
Delay
Delay
On
On
OFF
Off
A OUT
Analog Output
Rate
Rate output
29
Instruction Manual
Action/Setting
Enter Advanced menu
Setup open collector
outputs Out 1 and Out
2
Assign function of
open collector output 1
Assign function of
open collector output 2
Set Out 1 or Out 2 for
pulse output mode
Assign pulse output to
rate
Assign pulse output to
total
Assign pulse output to
grand total
Set K-Factor decimal
point
Set K-factor
Assign pulse output to
retransmit
Assign pulse output to
quadrature
Assign pulse output to
test mode
Assign Out 1 or Out 2
for alarm output mode
Assign alarm output to
rate
Set rate alarm set
point
Set rate alarm reset
point
Assign alarm output to
total
Assign alarm output to
grand total
Set total or grand total
alarm set point
Set output to on state
Set output to off state
Set Out 1 or Out 2 for
timed pulse output
mode
Activate timed pulse
output
Set the time of one
period (seconds)
Set the active low
pulse width
Set Out 1 or Out 2 as
off
Enter Analog Output
menu
Set rate as output
variable