YPP6830 Explosion-Proof Pulse Input Rate/Totalizer
Automatic Unit Conversions
When switching from any standard unit of rate, total,
or grand total to any other standard unit, automatic
unit conversions are performed by the meter.
No unit conversions will be performed when the
K-Factor Units (FuNiT) menu is set to custom (CUST).
A total or grand total unit conversion will automatically
change the displayed total and grand total to the
equivalent volume of the newly selected unit.
Custom Units Entry (USER)
When a custom unit is selected for rate, total, or grand
total, a User menu allows for entry of the custom unit.
Any 5-digit 14-segment unit may be entered for a
custom rate unit (example: mL).
Any 7-digit 14-segment unit may be entered for a
custom total or grand total unit (examples: GALLONS,
BOTTLES, DRUMS).
When selected for total or grand total, a custom unit
will not allow a multiplier prefix. A custom total or grand
total unit will allow a total or grand total conversion
factor to be entered to define the unit. See Custom
Units Total Conversion Factor (totCF) on page 26 for
details.
Fully alphanumeric values are set using the Right
button to select the digit to be changed. Press the Up
button to begin editing the digit, then the Up and
Right arrow buttons to select the next or previous
alphanumeric character. Press the Enter button to
confirm and select the next digit to change.
For details on setting alphanumeric labels, refer to
Setting Alphanumeric Labels (LABEL) on page 19.
Press Menu button to exit this menu without saving
changes.
Custom Units Rate Conversion
Factor (ratCF)
The rate conversion factor is only used when the Units
for rate have been set to custom (CUST). This menu will
not appear if standard display units are selected for the
rate unit.
Rate Conversion Factor is used to convert to a custom
unit of rate display. For example, to display rate as
quantity of 2.5 gallon containers when the K-Factor units
are set to gallons, enter a conversion factor of 2. 5 00.
Press the Enter button, at any time, to accept a setting
or Menu button to exit without saving changes.
Custom Units Total Conversion
Factor (totCF)
The total conversion factor is only used when the
Units for total have been set to custom (CUST). This
menu will not appear if standard display units are
selected for total.
Total Conversion Factor is used to convert to a
custom unit of total display. For example, to display
total as quantity of 2.5 gallon containers when the
K-Factor units are set to gallons, enter a conversion
factor of 2. 5 00.
Press the Enter button, at any time, to accept a
setting or Menu button to exit without saving changes.
Custom Units Grand Total
Conversion Factor (GrtCF)
The grand total conversion factor is only used when
the Units for grand total have been set to custom
(CUST). This menu will not appear if standard display
units are selected for grand total.
Grand Total Conversion Factor is used to convert to a
custom unit of total display. For example, to display
grand total as quantity of 2.5 gallon containers when
K-Factor units are set to gallons, enter a conversion
factor of 2. 5 00.
Press the Enter button, at any time, to accept a
setting or Menu button to exit without saving changes.
26