Grand Total Reading (Grtotal); Previous Total & Grand Total; Display Max, Min & Previous Totals - YOKOGAWA YPP6830-AP0-0 Instruction Manual

Explosion-proof pulse input rate/totalizer
Table of Contents

Advertisement

YPP6830 Explosion-Proof Pulse Input Rate/Totalizer
SafeTouch Button Tips and Troubleshooting
The SafeTouch Buttons are designed to filter normal
levels of ambient interference and to protect against
false triggering, however it is recommended that the
SafeTouch Buttons be turned off (slide THRU-GLASS
BUTTONS switch located on the back of the display
module to OFF) if there is an infrared interference
source in line-of-sight to the display or if the buttons
are not needed.
SafeTouch Button Tips:
• To the extent possible, install the display facing
away from sunlight, windows, reflective objects
and any sources of infrared interference.
• Keep the glass window clean.
• Tighten the cover securely.
• Use a password to prevent tampering.
• If the cover has not been installed and secured
tightly, it may take a moment for the SafeTouch
buttons to properly self-calibrate when the
cover is tightened.
After all connections have been completed and
verified, connect the ribbon cable to the display
module, fasten the display module to the base, install
enclosure cover, and then apply power.
SafeTouch Button Equalize Delay
The SafeTouch buttons are designed to constantly
recalibrate for ambient conditions. When the cover
position is changed, the cover is removed, or an object
is removed that was placed over the front window, it
may take a moment for the SafeTouch buttons to
recalibrate to the change in conditions.
Allow up to 2 minutes for the SafeTouch buttons to
recalibrate to new conditions in these cases where the
cover position was changed, or the front window is
being unblocked.

Grand Total Reading (GrTOTAL)

The grand total is a separate total that is not reset
when the total is reset. This allows the complete total
to be tracked by the grand total, while individual
batch, or daily totals are reset regularly.
To display the grand total, press the Up/Display
button. The display will read GRTOTAL, and the GT
symbol will appear indicating the grand total is being
displayed on the bottom display. After 10 seconds,
the bottom display will return to showing total. To lock
the grand total on the display, press Enter. Pressing
Menu at any time will return to normal Run Mode.
Note: If the Display menu has been setup to display the
grand total on the bottom display, pressing the Up/Display
button will display the maximum and minimum readings
followed by the total.
Previous Total & Grand Total
The previous total and grand total values, prior to
being reset, are stored in memory. These values can
be viewed using the Up/Display button.
Display Max, Min & Previous
Totals
The maximum and minimum (peak & valley) readings
reached by the rate are stored in the meter since the
last reset or power-up. The meter shows MAXIMUM or
MINIMUM to differentiate between Run Mode and
max/min display.
To display the maximum and minimum readings and
the previous total and grand total use Up/Display
button to cycle the bottom display. Maximum and
minimum are displayed after the grand total.
Press the Enter button to remain in Max / Min /
Previous display mode. If Enter is not pressed, the
Max / Min / Previous display readings will time out
after ten seconds. The meter will return to display the
actual reading. Pressing Menu at any time will return
to normal Run Mode.
47
Instruction Manual