Send And Monitor 511 - Paradyne HotWire 7976 User Manual

M/sdsl standalone termination unit with g.703 interface
Hide thumbs Also See for HotWire 7976:
Table of Contents

Advertisement

Send and Monitor 511

E1
LIU
AIS
Framer
7976-A2-GB20-10
The LTU initiates the test by sending a command to the remote unit to send a
511 test pattern. When the remote unit detects the command, it sends a
511 pattern and lights the front panel test LED. Each unit will send and monitor
the 511 pattern. The duration and results of the test are displayed on the Network
Test screen of each unit.
NOTE:
The send and monitor test is not a loopback test. Each unit independently
sends and monitors a 511 pattern.
511
CAP
Pattern
CAP
511
Gen
511
Pattern
511
Gen
Framer
Transceiver
Procedure
To run a Send and Monitor 511 test:
1. Position the cursor at the Start command next to Send and Monitor 511 on
the Network Tests screen.
2. Press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command.
4. Press Enter.
When a Send and Monitor 511 test is active, a count of bit errors is displayed next
to the test duration, and the ResetMon virtual function key is available for use.
Type r or R or select the ResetMon virtual function key to reset the error count.
August 1998
CAP
CAP
511
Gen
511
Gen
Framer
Framer
Transceiver
Testing
E1
AIS
G.703
LIU
Port
98-16002
5-7

Advertisement

Table of Contents
loading

Table of Contents