Paradyne HotWire 7976 User Manual page 103

M/sdsl standalone termination unit with g.703 interface
Hide thumbs Also See for HotWire 7976:
Table of Contents

Advertisement

The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-bindings are different for each particular interface. Diagnostic tests are
only supported on the physical E1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:
7976-A2-GB20-10
enterpriseTestStart/Stop
Interface
Variable-Bindings
SDSL
ifIndex (RFC 1573)
Network
ifAdminStatus (RFC 1573)
ifOperStatus (RFC 1573)
ifType (RFC 1573)
ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopLLB – Initiates a Local
Loopback.
– testLoopPLB – Initiates a
Payload Loopback.
– testLoopRLB – Initiates a
Remote Loopback.
– testSendMon511 – Initiates a
Send and Monitor 511 test.
– testSendLLBUp – Initiates an
LLB Up message to the remote
unit.
– testSendLLBDown – Initiates an
LLB Down message to the
remote unit.
G.703
ifIndex (RFC 1573)
ifAdminStatus (RFC 1573)
ifOperStatus (RFC 1573)
ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopExternalDTE
August 1998
Standards Compliance for SNMP Traps
Possible Cause
enterpriseTest Start – Any
one of the following tests is
active on the interface:
– Line Loopback
– Payload Loopback
– Repeater Loopback
– Remote Line Loopback
– Send and Monitor 511
enterpriseTest Stop – No tests
currently running on the
interface.
B-5

Advertisement

Table of Contents
loading

Table of Contents