Send And Monitor 511 - Paradyne Hotwire 7975 User Manual

Paradyne m/sdsl standalone termination unit user's guide
Hide thumbs Also See for Hotwire 7975:
Table of Contents

Advertisement

Testing

Send and Monitor 511

Port
All 1s
Interface
"
5-6
The LTU initiates the test by lighting the Test LED sending a command to the
remote unit to send a 511 test pattern. When the remote unit detects the
command, it sends a 511 pattern and lights the front panel test LED. Each unit
will send and monitor the 511 pattern. The duration and results of the test are
displayed on the Network Test screen of each unit.
NOTE:
The send and monitor test is not a loopback test. Each unit independently
sends and monitors a 511 pattern.
Local
NTU/LTU
511
Gen
CAP
Framer
511
Mon
Procedure
To run a Send and Monitor 511 test:
1. Position the cursor at the Start command next to Send and Monitor 511 on
the Network Tests screen.
2. Press Enter.
The Start command is changed to Stop.
3. To manually stop the test, verify that the cursor is positioned at the Stop
command.
4. Press Enter.
When a Send and Monitor 511 test is active, a count of bit errors is displayed next
to the test duration, and the ResetMon virtual function key is available for use.
Type r or R or select the ResetMon virtual function key to reset the error count.
December 1998
Remote
NTU/LTU
511 Pattern
511
Mon
CAP
Framer
511 Pattern
511
Gen
Port
EIA-530
All 1s
Interface
Port
98-15936
7975-A2-GB20-40