H Telco-Initiated Tests (Model 7974); Telco-Initiated Line Loopback - Paradyne 7974 User Manual

M/sdsl standalone termination units
Table of Contents

Advertisement

Testing
Telco-Initiated Tests (Model 7974)

Telco-Initiated Line Loopback

8-18
The Hotwire 7974 Standalone Termination Unit supports Telco-initiated tests as
shown in the following table.
Activation and
Line Loopback
Deactivation
In-Band Signal
Supported
Bit-Oriented
Supported
Message-Oriented
Not Applicable
The Hotwire 7974 Standalone Termination Unit supports line loopback as
specified in AT&T TR 54016, AT&T TR 62411, and ANSI T1.403. A Telco-initiated
line loopback loops the received signal on the DSX-1 interface back to the DSX-1
interface without modification. Framing, CRC, and FDL bits are returned
unaltered, and no BPVs or other line coding errors are removed.
CAP
DSL
All Ones
Port
Transceiver
August 2000
Payload Loopback
Not Applicable
Supported
Not Supported
CAP
T1
LIU
Framer
Framer
Remote Line
Loopback
Supported
Supported
Not Applicable
DSX-1
Telco
Port
99-16252