APPX. 4 ALERT LIST
Alert No.
ALF ID
ALR ID
30512,4
903
30603,1
273
30603,2
274
30603,3
275
30603,5
285
30603,6
276
30682,1
680
30682,2
681
30682,3
682
33035,1
634
33035,2
635
33035,3
636
33035,4
637
AP-18
Alert Name, Meaning and Remedy
Name: No HDG for FILT
Meaning: No valid heading sensor is available for filter.
(Banned or connection error)
Remedy: Check the connection with all GPS sensors.
Name: Lost Bow Depth
Meaning: Depth data of all available depth sensor(Bow)
has been not available for more than 3 seconds.
Remedy: Check the connection with all echo sounders.
Name: Lost MID Depth
Meaning: Depth data of all available depth sensor(Mid)
has been not available for more than 3 seconds.
Remedy: Check the connection with all echo sounders.
Name: Lost Stern Depth
Meaning: Depth data of all available depth sensor(Stern)
has been not available for more than 3 seconds.
Remedy: Check the connection with all echo sounders.
Name: Lost HDG MAG
Meaning: Heading data of all available magnetic gyro has
been not available for more than 3 seconds.
Remedy: Check the connection with all magnetic gyro.
Name: Lost Depth
Meaning: Depth data of all available depth sensors has
been not available for more than 3 seconds.
Remedy: Check the connection with all echo sounders.
Name: Watch End
Meaning: Watch is ending.
Remedy: Prepare to make turn(s).
Name: Repeated Timer
Meaning: The action set with repeated timer is approach-
ing.
Remedy: Take the actions scheduled in advance.
Name: Specified Timer
Meaning: The action set with specified timer is approach-
ing.
Remedy: Take the actions scheduled in advance.
Name: UKC Limit
Meaning: Measured depth from echo sounder is less than
set UKC limit value.
Remedy: Be careful that measured depth is less than UKC
limit.
Name: Non-official ENC
Meaning: A non-official ENC with warning and caution set-
tings was detected in the fore monitoring check area.
Remedy: Install official ENC.
Name: No Vector Chart
Meaning: A vector chart without warning and caution was
detected in the fore monitoring check area,
Remedy: Install latest vector chart.
Name: Not Up-to-date
Meaning: When Not Up to Date is set to Warning/Caution
in chart alert, a chart area that is not up-to-date is detected
inside the check area.
Remedy: Install latest chart.
Priority/
Category
Warning/B,
TCS
Caution/B
Caution/B
Caution/B
Caution/B
Caution/B
Warning/B
Warning/B
Warning/B
Warning/A
Warning/A
Warning/A
Warning/A