2. WIRING
<VDR connection>
• Do the settings in the [Common Installation Settings] menu. See the Instruction
Manual (E42-01204) for the procedure.
• To connect a IEC61162-450 compliant VDR (VR-7000/S), connect the VDR to the
LAN2 port.
• To connect a VDR that does not comply with IEC61162-450 (VR-3000/S), connect
the VDR to the DVI3 or DVI2 port.
Connections at the EC-3000/3005
Prepare the following cables and installation materials.
• When connecting a VDR to the DVI3 port:
Use a DVI-BNCX converter cable (type: DVI-BNCX5-L2000).
• When connecting a VDR to the DVI2 port:
Use a DVI/RGB converter (maker: IMAGENICS, type: DVI-12A, local supply).
Connections at the VDR (VR-3010)
See the VDR Installation Manual.
Setting for MU-190/MU-231/MU-270W
The [INSTALLATION SETTING] menu appears only when the power is turned on for
the first time after installation of the monitor unit.
INSTALLATION SETTING
EXT BRILL CTRL
SERIAL BAUDRATE
COLOR CALIBRATION
KEY LOCK
SAVE AND EXIT
Adjust the settings referring to the following table.
EXT BRILL
CTRL
RS-485
*: [DVI PWR SYNC] is the slide switch at the bottom rear of the monitor unit. Confirm
that this switch is set to [ON] (default setting). See "Slide switch" below for details.
Slide switch
Set the slide switch to "ON" (default setting). This setting automatically powers the
monitor unit on or off according to the DVI signal input. The power switch of the mon-
itor unit is inoperative.
Note: The OFF position provides control of the monitor unit power with the power
switch of the monitor unit.
2-14
RS-485
(OFF/DVI1/DVI2/RS-232C/RS-485/USB)
4800bps
(4800/9600/19200/38400)
ON
(OFF/ON)
ON
(OFF/ON)
YES
(NO/YES)
SERIAL
BAIDRATE
CALIBRATION
4800bps
Menu
COLOR
KEY LOCK
ON
ON
Menu item
DVI PWR
SYNC*
ON