Furuno FMD-3005 Installation Manual page 67

Table of Contents

Advertisement

Fabrication of TTYCS cable
100 or more
Vinyl tape
Clamp here by cable clamp.
Fabrication of TTYCSLA cable
Sheath
100 or more
Vinyl tape
Wiring for WAGO connector
WAGO driver
Wire
Twist
Procedure
1. Twist the conductor.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that is ecure.
• Connectors J3 to J6 on the I/O Board in the processor unit can be set to IEC 61162-
1 or IEC 61162-2. This console is shipped with the setting for IEC 61162-2.
• The connector J11 on the I/O Board in the processor unit can be set to the contact
input or digital input. This console is shipped with the setting for the contact input.
Armor
100
30
After exposing cores, wind
shield around the armor.
6
70
100
5
5
6
Clamp here by cable clamp.
WAGO
connector
Shield
Drain wire
Pass the drain wire through the shrink tube
(local supply), then attach the crimp-on lug
supplied in the console.
WAGO driver
Terminal board
(at the bottom of the console)
3. ECN-303/304 (OPTION)
3-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmd-3200Fmd-3300Fmd-3200-bb

Table of Contents