Furuno FMD-3005 Installation Manual page 27

Table of Contents

Advertisement

Connection
1. Unfasten four screws (M4x8) to remove the top cover from the processor unit.
2. Unfasten three bolts shown below to remove the upper plate of the cable clamp.
J4
J4
J8 J8
J6 J6
J12
J12 J13
J11
J11
J9 J9
J5 J5
J3 J3
J7 J7
J10
J10
Unfasten this bolt to use
Unfasten this bolt to use
the lower clamp holes.
the lower clamp holes.
Unfasten these three bolts to remove the upper plate.
3. Pass the cables through the clamp holes, then fasten the bolts removed at step 2
to fix the cables.
4. Connect the WAGO connectors appropriately to the I/O Board, referring to the in-
terconnection diagram.
J3 to J6: IEC 61162-1/2
J7 to J10: IEC 61162-1
J13
J11: Alarm system (System fail, Power fail,
J14
J14
J12: Main control unit
J13 and J14: Sub control units
Processor unit, top view
Normal close×2, Normal open×2, ACK IN)
Clamp holes (upper)
Clamp holes (lower)
Lay shields of cables
under this clamp then
tighten the clamp.
2. WIRING
2-7

Advertisement