Processor Unit - Furuno FMD-3005 Installation Manual

Table of Contents

Advertisement

2.1

Processor Unit

2.1.1
How to connect cables to terminals on the processor unit
Use screws (M3×6, supplied) to
attach the wiring plate 1 and
wiring plate 2 to the processor
unit. Connect the cables to the
connectors at the front of the
processor unit, referring to the
following figure. After the con-
nection, bind cables to the ap-
propriate fixing metal with the
cable ties (supplied).
For the cables from the monitor unit (type: DVI-D/D SLINK5M/10M (MU-190 only),
DSUB9P-X2-L5/10M) and ground wire, connect them to the processor unit directly
(without fixing to a wiring plate). Tighten the fixing screws on these connectors to pre-
vent disconnection from the processor unit.
Note: Connect the cables so that they do not interfere with the opening or closing of
the DVD tray.
LAN1
HUB-3000
(DTI-C5E350 VCV
cable)
Power cable
(IEC60320-C13-
L5M cable)
HUB-3000*/MC-3000S
HUB-3000: DTI-C5E350
VCV cable
MC-3000S: FR-FTPC-CY
cable, max. 50 m length
USB4
For USB printer
*: Use HUB-100 for IEC 61162-450 Ed.1 compliant network. (FMD-3200/3200-BB/3300 only)
Cables connected at the wiring plate 1
• USB cables from the control units
• Printer cable
• LAN cable (type: DTI-C5E350 VCV) from the HUB-3000
• LAN cable (type: FR-FTPC-CY) from the HUB-100/MC-3000S
Cables connected at the wiring plate 2
• Power cable (Type: IEC60320-C13-L5M)
• LAN cable to the LAN3 port
COM2
DVI3
Cable clamp
LAN2
USB1
RCU-024/026
(TS-20-071-1 cable)
LAN3
Not used.
USB2/3
Optional control unit
RCU-024/026
(TS-20-071-1 cable)
Wiring plate 2
Wiring plate 1
Monitor unit
(DVI3: DVI-D/D S-LINK cable
or DVI-BNCX5-L2000 cable,
COM2: DSUB9P-X2-L cable)
DVI2
(DVI2: DVI-D/D S-LINK cable)
Ground wire
(IV-2sq.,
local supply)
COM1
DVI1
Monitor unit
(DVI1: DVI-D/D S-LINK cable,
COM1: DSUB9P-X2-L cable or DSUB9P-X2-A-L cable)
2. WIRING
Monitor unit
2-3