DocuTech 61xx Operator Guide
Figure 6-15. Locating the Q1205, Q1206, and Q1207
sensors
4. Brush a folded sheet of paper across each sensor to clear
any obstruction.
5. Close the bindexer and finisher doors.

Clearing the Q1213 sensor

Clearing the Q1213 sensor should be performed only when
directed by a Customer Support Center Representative.
NOTE: Perform the following when it is necessary to clear the
Q1213 sensor.
1. Open the finisher doors.
The top of the binder is approximately 425°F (218°C). Do not
touch the heated areas or you may get burned. If the binder
has been in a "Ready" condition, allow it to cool for at least
1 hour before continuing the procedure.
2. Grasp the green handle on the binder drawer. Pull the
drawer out until it stops.
3. Locate the Q1213 sensors, as shown in figure 6-16.