Mitsubishi MELSEC F FX-40DU-E Handy Manual page 51

Table of Contents

Advertisement

4.
USER SCREEN MODE
4.6
Screen Change
by
Direct Specification
of
Screen Number
This section describes the case where the destination screen is specified using a number key.
This example is applicable to the display of work instructions for the attention of the operator, or setting
of conditions for an operation, where the screens displayed are predetermined by the change conditions.
Example: Operation settings
.....
Setting of the operation time for each process.
[CHANGE SCREEN] (common setting)
1
/
0
1
NONE
1
0
Screen No.0 (menu selection screen)
Screen change conditions
Operation Settings
1 Stage 1
Number of products
The I 0
1
kev returns the d i s ~ l a v to the menu screen
Screen
specification
(destination)
Key
2 Stage
2
Drilling process time
3 Stage
3
Number of screws
4 Stage 4
Conveyor travel
5
Stage 5
Product packaging
Select from 1 to
5
Screen
'lored
Device
I
Screen No.1
:Change
:Complete
Next
screen
: Display
menu
I
L
Calls up rnenu screen (NaO)
Screen No.6
Checking time
20 seconds
Time to release
10 seconds
I
NO
. .
,
,
,
--
(NO.~).
ICHANGE SCREEN1 Screen No. 0 settinq
-
1
2
3
M O is controlled by the
controller to remain ON
during operation.
Programmable controller program
During operation
Screen
'lored
Screen change conditions
Kev
1
Device
4
The screen cannot be changed just by pressing keys during
operation. The screen will only change when both key and
device conditions are met.
[CHANGE SCREEN] Screen No. 1 setting
Screen
specification
(destination\
4
I
MOOFF
I
4
I
NO
I
1
2
3
1
2
3
The [CHANGE SCREEN] object will cause the displayed
screen to change to screen No.6 on pressing the
[ V ]
key.
Pressing the [ 0 ] key will cause a return to the menu screen
(this is common to all screens).
[CHANGE SCREEN1 Screen No. 6 setting
N O
NO
NO
MO OFF
MO OFF
MO OFF
N O
5
Screen
"Umber 'lored
I
I
I
Screen
specification
(destination)
Screen change conditions
:Change
:
complete
: Prev~ous screen
:Display menu
5
Key
NO
i
Displays the previous
i
screen
Calls up menu screen (No.0)
(this is 6ommon to d l screens).
Device
If the production target of 100 is input as a [NUMBER] object,
it will be possible to change this value while the screen is dis-
played by pressing the [SET] key.
6
1
Screen
'lored
Screen change conditions
Key
1
Device
MO OFF
Screen
specification
(destination)
5
V
,
1
I
'
NONE
1
If the checking time and time spent waiting for release are
both input as [NUMBER] objects, it will be possible to change
their values while the screen is displayed by pressing the
[SET] key.
The [CHANGE SCREEN] object will cause the displayed
screen to change to screen No.1 on pressing the [ A ] key.
Pressing the
[
0 ] key will cause a return to the menu screen
NO
A
NONE
1

Advertisement

Table of Contents
loading

Table of Contents