CAMSHAFT
JOURNAL
WEAR
Determine
whether
each journal
is worn down to
the limit or not by measuring camshaft journal oil
clearance
with
the camshaft installed. Use plasti-
gauge to read the clearance, which
is specified as
follows:
Camshaft journal oil clearance
Service Limit
0.12 om
es
(0.0059 in)
e Tighten the cylinder head cover bolts evenly and
diagonally to the specified torque.
Cylinder head cover tightening torque
9—11N-m
Tightening torque
ee -—1.1 Rae)
6.5 — 8.0 Ib-ft
09900-22301
Plastigauge
Micrometer
09900-20205
(0 — 25 mm)
Camshaft journal
24.959 — 24.980 mm
ODO aae
(0.9826 — 0.9835 in)
Center)
Camshaft journal
19.959 — 19.980 mm
O.D. (Left)
(0.7858 — 0.7866 in)
CAMSHAFT
RUNOUT
Measure
the runout
with
a dial gauge.
Replace
the camshaft if the runout exceeds the limit.
:
'3°
0.10 mm
Service Limit
(0.004 in)
NOTE:

Advertisement