Micrometer
09900-20205
(0 — 25 mm)
falve stem O.D.
Standard
6.960 — 6.975 mm
(0.2740 — 0.2746 in)
6.945 — 6.960 mm
(0.2734 — 0.2740 in)
12.3 mm reamer
Handle
09916-34531
09916-34541
» Fit a ring to each valve guide. Be sure to use
new
rings and
valve
guides.
Rings
and
valve
guides
removed
in disassembly
must
be dis-
carded.