8.4

Electromagnetic compatibility

See the note in "Applicability of technical specifications (Page 75)".
Interference emission
Emitted interference
Noise immunity on supply lines
Noise immunity on signal lines
Immunity to discharges of static
electricity
Immunity to RF interference
Magnetic field
: With a clamp filter(Ferrite Core with Case) on the DVI-D cable near the DVI-D port of the IPC
1
RW-543A, you need to meet the following requirements:
• The impendence of the clamp filter need to be at least 200 ohm at 100MHz to 1000MHz.
• The aperture of the clamp filter and inner diameter of DVI-D cable should be as close as
possible.
SIMATIC IPC RW-543A
Operating Instructions, 03/2023, A5E52332059-AA
EN 61000-6-4
CAN/CSA CISPR32:17 Class A, EN 55032 Class A; FCC Class A;
EN 61000-3-2 class D, EN 61000-3-3
Conducted Emission (AC): IEC 61000-6-4 + A1, IEC 61131-2
0.15 to 0.5 MHz: 79 dB (μV) QP, 66 dB (μV) A
0.5 to 30 MHz: 73 dB (μV) QP, 60 dB (μV) A
Conducted Emission (Telecommunications/network): IEC 61000-6-4 + A1
0.15 to 0.5 MHz: 97 dB (μV) - 87 dB (μV) QP, 84 dB(µV) – 74 dB(µV) A
0.5 to 30 MHz: 87 dB (μV) QP, 74 dB (μV) A
Radiation Emission: IEC 61000-6-4, CISPR 32:17
30 to 230 MHz: 40 dB(μV/m) QP (10 m distance)
230 to 1000 MHz: 47 dB (μV/m) QP (10 m distance)
1 to 3 GHz: 76 dB (μV/m) P; 56 dB (μV/m) A (3 m distance)
3 to 6 GHz: 80 dB (μV/m) P; 60 dB (μV/m) A (3 m distance)
Harmonic currents: EN 61000-3-2 class D
Voltage fluctuation and flicker: EN 61000-3-3
± 2 kV; according to IEC 61000-4-4; burst
± 1 kV line-to-line; according to IEC 61000-4-5; surge
± 2 kV line-to-earth; according to IEC 61000-4-5; surge
± 2 kV; according to IEC 61000-4-4; burst; length > 30 m
± 1 kV ; according to IEC 61000-4-4; burst; length < 30 m
± 2 kV shielding-to-earth; according to IEC 61000-4-5; surge; length > 30 m
± 4 kV contact discharge (according to IEC 61000-4-2)
± 8 kV atmospheric discharge; (according to IEC 61000-4-2)
Radiation Immunity (according to IEC 61000-4-3)
10 V/m; 80 up to 1000 MHz
80% AM (1 kHz)
3 V/m; 1.4 to 2 GHz
80% AM (1 kHz)
3 V/m; 2 to 6 GHz
80% AM (1 kHz)
Conducted Immunity (according to IEC 61000-4-6)
150 kHz to 80 MHz: 10 V, 80% AM (1 kHz)
30 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)