Table of Contents

Advertisement

Quick Links

4011-3XXXSIMATIC IPC RW-543A
SIMATIC
Industrial PC
SIMATIC IPC RW-543A
Operating Instructions
03/2023
A5E52332059-AA
Preface
Product description
Safety instructions
Installing and connecting
the device
Commissioning the device
Operating the device
Expanding and assigning
parameters to the device
Device maintenance and
repair
Technical specifications
Dimension drawings
Standards and approvals
BIOS description
Hardware description
Technical support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
8
9
10
11
A
B
C
D

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC RW-543A

  • Page 1 4011-3XXXSIMATIC IPC RW-543A Preface Product description SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC RW-543A Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    General knowledge in the field automation control engineering is recommended. Range of validity of these operating instructions These operating instructions are valid for all supplied versions of the SIMATIC IPC RW-543A. History Currently released versions of these operating instructions:...
  • Page 4 Preface SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 5: Table Of Contents

    3.1.2 Checking the delivery package ................... 32 3.1.3 Device identification data ....................32 Mounting the device ......................34 3.2.1 Mounting types ......................... 34 3.2.2 Securing device ......................... 35 Connecting the device ....................... 37 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 6 Installing operating system, software and drivers ............... 71 7.4.1 Installing software and drivers ................... 71 Recycling and disposal ....................... 74 Beep code.......................... 74 Technical specifications ........................75 Applicability of technical specifications ................75 General technical specifications ..................75 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 7 USB 2.0 port ........................116 A.2.3 Serial interface ......................... 116 A.2.4 Ethernet .......................... 117 A.2.5 HDMI ..........................118 Internal Connector ......................118 A.3.1 Fan connector ......................... 118 A.3.2 Front panel connector ...................... 119 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 8 Problems when using expansion cards ................132 Markings and symbols ........................133 Overview ......................... 133 Safety ..........................133 Operator controls ......................133 Certificates, approvals and markings ................134 Interfaces ........................135 List of abbreviations .......................... 137 Index ..............................139 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 9: Product Description

    Windows® operating Information on: • Supplied data storage medium system • Commissioning the operating • Online at: system Microsoft® Windows® 10 • Restoring the operating system (https://support.industry.siemens. • Configuration of the operating com/cs/ww/en/view/109749498) system SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 10: Product Highlights

    1.2 Product highlights Product highlights The SIMATIC IPC RW-543A is an industrial PC in 19" rack format design (4U). It is perfectly suited for PC applications with high-level industry functionality. • Powerful processors up to Intel Core i9 (10th generation) •...
  • Page 11: Scope Of Application

    The SIMATIC IPC has CE certification for use in the industrial sector as well as in residential and commercial areas and small businesses. In addition to the industrial applications, therefore, it can also be used in building automation or in public facilities. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 12: External Design Of The Device

    USB 1.1 ③ On/off button ⑧ HDD status display ④ Connection for USB 2.0 devices, ⑨ Power status display compatible with USB 1.1 ⑤ Drive bays 3 x 5.25" 1.4.2 Rear of the device SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 13: Drive Cage

    ② Mounting location 2 Mounting location for 3.5" or 2.5" drive in a shock-proof/vibration- proof fixture or for 5.25" drive or components ③ Mounting location 3 Mounting location for 3.5" or 2.5" drive in a shock-proof/vibration- proof fixture or for 5.25" drive or components SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 14: Interfaces And Connections

    Connection for microphone, 3.5 mm phono jack ⑧ RJ45_USB2 (USB) Dual USB3.0 TYPE-A Connector X62/X63/X64/X65 ⑨ HDMI X72 HDMI TYPE-A Connector ⑩ VGA X71 VGA DB15/F Connector ⑪ USB X60/X61 Dual USB2.0 TYPE-A Connector SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 15: Power Supply Connections

    The buttons and switches described in the following do not fully disconnect the device from the line voltage. You also need to the notes and information under "Switching off the device (Page 44)". SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 16 10 seconds. Automatic startup may endanger the operation of the machine or plant, for example, after a power failure. Take this into account when designing the plant. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 17 Perform a hardware reset only in the case of an emergency. Close all running programs. Make sure that there is no more read or write access to drives and I/O before performing the hardware reset. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 18: Status Displays

    The Ethernet interfaces are numbered on the enclosure to identify them clearly. The numbering by the operating system can differ. Status display Meaning Status Meaning of the status LED 1 Data transmission rate 10 Mbps Green 100 Mbps Orange 1000 Mbps SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 19: Internal Construction Of The Device

    ③ Motherboard with slots for memory slots ④ Drive cage ⑤ Motherboard ⑥ Slots for expansion cards ⑦ Card holder for expansion cards ⑧ On the enclosure: Numbering of slots for expansion cards SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 20 Product description 1.5 Internal construction of the device SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 21: Safety Instructions

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 22 • Disconnect the device from the power supply in good time when a thunderstorm is approaching. • Do not touch power cables and data transmission cables during a thunderstorm. • Keep sufficient distance from electric cables, distributors and systems. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 23: Disclaimer For Third-Party Software Updates

    Take corresponding precaution measures before you open the device. Disclaimer for third-party software updates This product includes third-party software. Siemens AG only provides a warranty for updates/patches of the third-party software, if these have been distributed as part of a Siemens software update service contract or officially released by Siemens AG.
  • Page 24: Note On Transport And Storage

    • Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 25: Notes On Mounting

    Touching these areas or components can cause death or serious bodily injury. • Always disconnect the cabinet from the mains before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 26: Notes On Ambient And Environmental Conditions

    • Install the device in a way that no danger is posed. • Always maintain a minimum clearance of 50 mm to the area of the ventilation slots and do not cover the ventilation slots of the enclosure. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 27: Information On I/O Devices

    • Only connect I/O devices which are approved for industrial applications in accordance with IEC/EN 61000-6-2 and IEC/EN 61000-6-4. • I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 28: Notes On Device And System Extensions

    • Always disconnect the power plug before you open the device. • Only install device or system expansions designed for this device. • Observe the information on "Electromagnetic compatibility" provided in the technical specifications. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 29 • UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 30 Safety instructions 2.9 Notes on device and system extensions SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 31: Installing And Connecting The Device

    • Software and tools to recover your ordered Microsoft® Windows® operating system • Device drivers for installation in operating systems • SIMATIC IPC RW-543A Quick Install Guide • SIMATIC IPC RW-543A Operating Instructions • Operating instructions for your ordered Microsoft® Windows® operating system on this device •...
  • Page 32: Checking The Delivery Package

    The device can be clearly identified with the help of this identification data in case of repairs or loss. The following illustrations are examples. The data of your device may differ from the data in these examples. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 33 ⑤ (MAC address) COA label The COA label (Certificate of Authenticity) is located inside the front door. Note The COA label is only available for devices delivered with Microsoft® Windows® operating system installed. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 34: Mounting The Device

    • Ensure that the installed device does not pose a danger, for example, hit someone by falling over. • All the external circuit of the device must be SELV circuit. Horizontal: Mounting on angle brackets The device can be installed horizontally in control cabinets and 19" rack systems. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 35: Securing Device

    Touching these areas or components can cause death or serious bodily injury. • Always disconnect the cabinet from the mains before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 36 The figure below shows the position of the mounting holes for angle brackets or telescopic rails. ① Threaded holes for 3A68-508APZZ3CEB 84H341300 telescopic rails from the company KING SLIDE WORKS CO., LTD or other telescopic rails match the dimensional and technical requirements. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 37: Connecting The Device

    • Conductor cross-section ≤ 18 AWG • Cable length ≤ 4.5 m 220V supply voltage • Type RVV with three conductors • conductor cross-section ≤ 18 AWG • Cable length ≤ 4.5 m SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 38: Connecting The Function Earth

    Firmly attach the cable lug to the function earth connection on the device using the M4 thread (see part labeled). Connect the function earth to the protective conductor connection of the cabinet or the plant in which the device is installed. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 39: Connecting The Power Supply

    2. Insert the power cable in the corresponding electrical socket. Information on the position of the socket is available in "Power supply connections (Page 15)". 3. Insert the power cable in the electrical socket. 4. Switch the on/off switch to on (position " | "). SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 40: Connecting I/O Devices

    • Audio device with line in • Headphones • Microphone • Headset (with headphones and microphone) with the following standards: – OMTP: Standard for audio devices from Nokia, etc. – CTIA: Standard for audio devices from Apple® SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 41: Connecting Device To Networks

    You can operate on up to three monitors with the VGA, DVI and HDMI cables. The output on the extended monitor can be the same as the main monitor or the extension desktop of the main monitor. You can configure it in windows screen and display setting. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 42 Installing and connecting the device 3.3 Connecting the device SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 43: Commissioning The Device

    "Operator controls (Page 15)". The green POWER LED lights up. The module carries out a self-test. 2. Follow the instructions on the screen. Press <ESC> or <DELETE> to enter setup. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 44: Switching Off The Device

    • Shut down the operating system and unplug the power plug from the rear of the device, see "Power supply connections (Page 15)". The device is switched off and fully disconnected from the mains voltage. No trickle current is flowing. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 45 • Press the on/off button for more than 4 seconds. – The unit switches off. – Press the power button again to turn the device back on. Information on the position of the buttons is available under "Operator controls (Page 15)". SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 46 Commissioning the device 4.2 Switching off the device SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 47: Operating The Device

    Operating the device Opening the front door Procedure 1. Unlock the front door with the key ①. 2. Open the front right door in the direction of the arrow. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 48: Monitoring Functions

    [Maximum Mode]: Uses Maximum speed • SYS_FAN2 Mode: – [Automatic Mode]: Chassis Fan speed change based on mother board temperature. – [Silent Mode]: Chassis Fan speed keep stable and no noise. – [Maximum Mode]: Uses Maximum speed SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 49: Expanding And Assigning Parameters To The Device

    The device contains electronic components that may be destroyed by electrostatic charges. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 50 • All connection cables are unplugged. • PH2 screwdriver Procedure 1. Remove the retaining screws ①. 2. Move the cover in the direction as the arrow. 3. Lift the cover from the back and remove it. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 51: Expansion Cards

    • You are familiar with the information on expansion cards and the conditions of use of expansion cards, see "Useable expansion cards (Page 51)". • The device is open, see important information in "Open the device (Page 49)". SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 52 1. Remove the retaining screw and remove the card holder. 2. Remove the slot bracket of the slot for the expansion card. 3. Insert the expansion card into the slot. 4. Secure the expansion card with the designated screw. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 53: Memory Modules

    The memory capacity of the device can be upgraded to a maximum of 128 GB. The table below shows the supported memory types of motherboard. Module type Module Size Description DDR4‐SDRAM 4 GB DDR4-2400/2666/2933MHz-UDIMM-288pin DDR4‐SDRAM 8 GB DDR4-2400/2666/2933MHz-UDIMM-288pin DDR4‐SDRAM 16 GB DDR4-2400/2666/2933MHz-UDIMM-288pin SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 54: Installing Memory Modules

    • DDR2 and DDR3 memory modules are not compatible. Please make sure to install DDR4 Memory Module on this motherboard. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 55: Drives (Hdd/Ssd)

    Drives (HDD/SSD) 6.4.1 Installation options for drive The drive modules are horizontal slot. The SSD and HDDs (with a 5.25" to 2.5" converter) can be installed in the slots. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 56: Removing The Drive Module

    Vibrations above 500 Hz are not permitted. 6.4.2 Removing the drive module Requirement • The device is fully disconnected from the line voltage, see Switching off the device (Page 44). • PH2 screwdriver SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 57: Installing The Drive (Hdd/Ssd)

    • The device is fully disconnected from the line voltage, see "Switching off the device (Page 44)". • The device is open, see important information in "Open the device (Page 49)". • The drive bay is taken out of the chassis. • PH2 screwdriver SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 58: Removing And Installing Internal Hdd/Ssd

    • The device is fully disconnected from the line voltage, see "Switching off the device (Page 44)". • The device is open, see important information in "Open the device (Page 49)". • The drive bay is taken out of the chassis. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 59 Loosen the four screws ① on the drive bay plate and remove the hard disk from the drive bay. Procedure for installing the hard disk drive Place the hard disk onto the drive bay plate and secure the drive with four screws ①. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 60 Expanding and assigning parameters to the device 6.4 Drives (HDD/SSD) SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 61: Device Maintenance And Repair

    PC components that are subject to wear. The table below indicates the intervals for this replacement. Component Replacement interval Drives 3 years Backup battery 5 years 5 years Filter pad Depending on the degree of soiling SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 62: Removing And Installing Hardware

    4. Pull the marked screw to open the fan bracket. 5. Remove the filter in the direction of the arrow. Procedure - Installing the filter To install the filter, follow the steps for removing it in reverse order. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 63: Replacing The Device Fan

    Procedure - Installing the fan To install the fan, follow the steps for removing it in reverse order. During installation, make sure that the arrow on the fan points away from the fan bracket. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 64: Changing The Backup Battery

    – Rated voltage: 3 VDC – Max abnormal charging current: 10 mA • For any requirements on product maintenance, contact Siemens Technical support (Page 129). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 65 – Courant de charge anormal max. : 10 mA • Pour toute demande concernant la maintenance du produit, contactez le support technique (Page 129) Siemens. • Ne jetez pas au feu des piles au lithium, n'effectuez pas de soudage sur la pile, ne la rechargez pas, ne l'ouvrez pas, ne la court-circuitez pas, n'intervertissez pas les pôles, ne...
  • Page 66 4. Close the device. 5. Reconfigure the BIOS setup. Note The configuration data of the device may be deleted when the battery is replaced. Record the current configuration data in the BIOS setup. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 67: Changing The Power Supply

    7. Connect the cables to the drives and the motherboard. 8. Use cable ties to reattach the power supply cables to the enclosure. 9. Close the device. 10.Check the safe state of the device. 11.Switch on the power supply. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 68: Replacing The Processor

    • Operate the processor only at a clock frequency that is equal to or less than the permitted clock frequency. Procedure 1. Unlatch the fan rack on the heat sink and remove it. 2. Remove the highlighted fan connector. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 69 7. Install the new processor on the socket, as shown in the figure. When installing the CPU, make sure you aligned the highlighted arrow on the processor with pin 1 in the CPU socket. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 70: Replacing The Motherboard

    Processor type and clock frequency If you use a processor of a different type, perform the BIOS update firstly. During the BIOS update, the microcode matching the processor is loaded. Contact the SIEMENS support to update the BIOS if you changed a different processor.
  • Page 71: Installing Operating System, Software And Drivers

    • Windows 10 operating system is installed in your IPC. • You need to connect a mouse, a monitor and a keyboard to your PC. • You also need the supplied USB stick to your PC. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 72 Step 2: install the Management Engine driver 1. Click Step 2: Install: Intel(R) Management Engine. 2. Click to install the Management Engine driver. 3. Click Yes to confirm the user account control question. 4. Click Next to continue. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 73 4. Click Next to continue. 5. Select the radio button next to “Yes, I want to restart my computer now.” and click Finish to restart the computer for the changes to take effect. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 74: Recycling And Disposal

    Due to their low level of pollutants, the devices described in these operating instructions can be recycled. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. Beep code Beeps Description 1 short beep Memory training success Beep loop Memory error SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 75: Technical Specifications

    850 W: 100 V AC to 240 V AC; 12A to 6A; 47-63Hz • Rated output power: – 350 W: (+3.3 V & +5 V≤105 W) – 500 W: (+3.3 V & +5 V≤105 W) – 850 W (+3.3 V & +5 V≤200 W) SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 76 Device is designed for connection to supply with overvoltage category II (transient overvoltages up to 2500 V) Safety regulations • IEC/EN/UL 61010-1 • IEC/EN/UL 61010-2-201 • IEC/EN/UL 62368 • CAN/CSA-C22.2 No. 61010-1 • CAN/CSA-C22.2 No. 61010-2-201 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 77: Current/Power Requirements And Power Supply

    +12 V2 17 A ± 5% –12 V 0.3 A ± 10% +5 VSB 2.5 A ± 5% The total output of +3.3 V and +5 V voltage must be ≤ 105 W. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 78 The continuous maximum total output power must be ≤ 850 W. • For +12 V DC: Maximum output power 70 A (840W) • For +3.3 V and +5 V DC: Maximum combined output power must be ≤ 200 W. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 79: Electromagnetic Compatibility

    • The impendence of the clamp filter need to be at least 200 ohm at 100MHz to 1000MHz. • The aperture of the clamp filter and inner diameter of DVI-D cable should be as close as possible. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 80: Ambient Conditions

    Information on the drives is available in your order documents. Drive Maximum number of drives Types of drive 2 (depends on the selected • 3.5" SATA, 6 GB/s; 1 TB configuration) • 256 GB • 512 GB SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 81: Technical Specifications Of The Motherboard

    Dynamic Video Memory Technology, uses 32 MB and 1.7 GB RAM in main memory Resolutions/frequencies/colors • HDMI up to 4096 x 2160@30Hz • VGA up to 1920 x 1200@60Hz • DVI-D up to 1920 x 1200@60Hz SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 82: Technical Specifications Of The Interfaces

    Full extraction length ≥ 470 mm Rail thickness ≤ 9.7 mm Mounting screws M5 x 6 mm The mounting screws of the telescopic rails may not protrude by more than 5 mm into the enclosure. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 83: Technical Specifications Of The Operating Systems

    Compatibility". The device is designed for the following areas of application corresponding to the CE marking: Scope of application Requirements for Interference emission Immunity to interference Industrial area EN 61000-6-4:2007 +A1:2011 EN 61000-6-2:2005 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 84: Esd Guideline

    The material with which an electrostatically-charged person comes into contact is of particular significance. The figure shows the maximum electrostatic voltages with which a person is charged, depending on humidity and material. These values conform to the specifications of IEC 61000-4-2. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 85 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically by touching grounded metallic parts before you take a measurement at a module. Always use grounded measuring instruments. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 86 Technical specifications 8.12 Directives and declarations SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 87: Dimension Drawings

    Dimension drawings Front view and top view All dimensions in mm. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 88: Dimension Drawing Of The Expansion Cards

    Dimension drawing of the expansion cards Long PCI card, PCIe card Dimension drawing of the telescope rails Dimensions for bore holes for telescopic rails Dimensions: mm T1=Tolerances of ± (0.1mm)/(0.004") T2=Tolerances of ± (0.3mm)/(0.01") SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 89: Standards And Approvals

    RoHS EN IEC 63000:2018 ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets the requirements of ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018. Certificate registration no. 01 100 1430201, 01 104 1430201 and 01 113 1430201.
  • Page 90 This product meets the requirements of the standard IEC/EN 61000-6-4 and AS/NZS 61000.6.4; Generic standards - Emission standard for industrial environments. This product meets the requirements of the standard IEC/EN 61000-6-4 and AS/NZS 61000.6.4; Generic standards - Emission standard for industrial environments. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 91 備考 3. "-" 係指該項限用物質為排除項目。 Note 3: The "−" indicates that the restricted substance corresponds to the exemption. Responsible party for Supplier's Declaration of Conformity 西門子股份有限公司 臺北市 11503 南港區園區街 3 號 8 樓 電子郵件信箱: (Adscs.taiwan@siemens.com) SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 92 DI FA TI COS TT P.O. Box 1963 D-92209 Amberg The UK Declaration of Conformity is also available for download from the Siemens Industry Online Support website under the keyword "Declaration of Conformity". WEEE label (European Union) Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 74) ".
  • Page 93: Bios Description

    To enter BIOS Setup at startup: 1. Power on the device. 2. Press ESC key on your keyboard during the Power - On - Self - Test (POST) when the SIEMENS logo is shown on screen. The Aptio TSE main BIOS setup menu is displayed.
  • Page 94 • Save & Exit: For selecting the exit options and loading default settings. Function description fields Function description fields are at the top right corner of the menu screen and a brief description of the selected item. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 95: Main Menu

    The Main menu provides you an overview of the basic system information, and allows you to set the system date and time. Note Take the BIOS version installed on your IPC as standard. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 96 2. Navigate to the hour, minute and second and type in the value as you need. Press Enter to jump to next filed. 3. Press F10 key and save the change. Note Enter the time in the 24-hour format. For example, you should enter 06:30:00 for 6:30 AM. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 97: Advanced Menu

    Enable or disable the intel virtualization technology. [Enabled] • [Enabled] Virtualization • [Enabled]: A VMM can utilize the additional hardware • [Disabled] Technology capabilities provided by Vanderpool Technology. • [Disabled]: Disable this function. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 98 Enable or disable the High Precision Event Timer. [Enabled] • [Enabled] Precision • [Disabled] Timer Refer to the following table to select the correct configuration options for Primary Display when you connect external graphic cards. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 99 • [Enabled] • [Disabled] PCIE_16X_SLOT1 Configure PEG 0:1:0 Max Speed. [Auto] • [Auto] Speed • [Gen1] • [Gen2] • [Gen3] PCIE_16X_SLOT2 Enable or disable the PCIE_16X_SLOT2. [Enabled] • [Enabled] (MaxWidth 8x) • [Disabled] SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 100 [Gen1] • [Gen2] • [Gen3] Detect Non-Compliance PCI Express Device in [Disabled] • Detect Non- • [Enabled] PCIE_4X_SLOT3. Compliance • [Disabled] Device PCI1&PCI2 SLOTS Control the PCI Slots. [Enabled] • [Enabled] • [Disabled] SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 101 Enable or disable Me FW Image Re-Flash function. [Disabled] Me FW Image Re- • • [Enabled] Flash • [Disabled] Enable or disable Me FW update function. [Enabled] • FW Update • [Enabled] • [Disabled] SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 102 Enable or disable the serial port (COM) 3. [Enabled] • [Enabled] • Serial Port • [Disabled] COM4 Enable or disable the serial port (COM) 4. [Enabled] • [Enabled] • Serial Port • [Disabled] SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 103 Enable or disable the USB X64. [Enabled] • [Enabled] • [Disabled] USB X65 Enable or disable the USB X65. [Enabled] • [Enabled] • [Disabled] Internal Enable or disable the Internal USB2_1. [Enabled] • [Enabled] USB2_1 • [Disabled] SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 104 Enable or disable the LAN X2P1 PXE BOOT. [Disabled] • [Enabled] PXE BOOT • [Disabled] Add-on PCIE Enable or disable the Add-on PCIE LAN card PXE Boot. [Disabled] • [Enabled] LAN card • [Disabled] PXE Boot SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 105: Hardware Monitor Menu

    [Maximum Mode Mode] • [Maximum Mode]: Uses Maximum speed. • [Automatic • [Automatic Mode]: CPU Fan speed change based on CPU Mode] temperature. • [Silent Mode] • [Silent Mode]: A lower sound mode. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 106: Security Menu

    Select Security item in BIOS Setup screen to enter Security menu. Administrator Password This option allows you to set an administrator password level password for BIOS. If you have set an administrator password, Siemens recommends that you enter the administrator password for accessing the BIOS. To set an administrator password: 1.
  • Page 107 Follow the same steps as in changing a user password, but click OK when prompted to create/confirm the password. Note Record the new password when the password is changed. If you forget the password, you can contact Siemens Technical support. Trusted Computing This option allows you to configure trusted devices: System parameters...
  • Page 108: Boot Menu

    [Enabled] • [Enabled] • [Disabled] USB Boot Enable or disable the USB Boot option. [Disabled] • [Enabled] • [Disabled] NVMe Boot Enable or disable the NVMe Boot option. [Disabled] • [Enabled] • [Disabled] SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 109: Save & Exit Menu

    UEFI Hard Disk Drive BBS Priorities In the UEFI Hard Disk Drive BBS Priorities page, you can modify the boot up screen between POST message and SIEMENS logo. The actual system parameter depends on the above configuration option for Fixed BOOT order Priorities.
  • Page 110 BIOS description 11.7 Save & Exit menu SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 111: Hardware Description

    Slot for CPU Fan and processor ③ Backup battery ④ Slots for memory modules Technical features of the motherboard Technical features of the motherboard can be found under "Technical specifications of the motherboard (Page 81)". SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 112: Position Of The Interfaces On The Motherboard

    COM1 DB9/M Connector HDMI TYPE-A Connector ⑦ Full-Size SIM Card Slot ⑯ Dual USB3.0 TYPE-A Connector2 ⑧ USB2.0 Internal Vertical TYPE-A ⑰ Microphone Connector Line OUT Line IN ⑨ ATX 24P Power Input Connector SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 113: Jumpers

    • The screws are not allowed to connect with motherboard circuit or components. The motherboard can be damaged by this action. • Do not leave the screws or the metal components on the motherboard or inside of the chassis. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 114 Clear CMOS CMOS Clear Jumper Pin setting Function 1-2(Default) Normal Clear CMOS NOTICE Set the jumper back to protected mode after clearing CMOS. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 115: External Interfaces

    Audio AUDIO1 3.5 mm jack 1. Line-In 2. Line-Out 3. Mic-In DVI VGA1 Connection of an analog monitor PS/2 X10 PS/2_USB1 PS/2 Connector (Keyboard and Mouse) DVI X70 DVI-I 24+4P/F Connector (Support DVI-D) SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 116: Usb 3.0 Port

    USB 2.0 port Short description Meaning USB_P5V_fused (O) +5 V, fused USB_D0M (I/O) Data– USB_D0P (I/O) Data+ USB_GND A.2.3 Serial interface RS232 Pin assignment RS232 Short description Meaning Data carrier detect (I) Received data (I) SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 117: Ethernet

    Green: 100 Mbps • Orange: 1000 Mbps LED 2 – • Off: Stop • Yellow: Active connected • Yellow flashing: Data transfer active The Ethernet interface supports MDXI (auto crossover) for all transmission rates. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 118: Hdmi

    TMDS clock+ Internal Connector A.3.1 Fan connector The pin assignment in the table below applies to all fan connectors on motherboard. FAN Header Pin setting Function +12V FAN Speed Detection FAN Speed Control SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 119: Front Panel Connector

    POWER 3.3V LED+ HDD 3.3V LED- POWER 3.3V LED- RESET- POWER+ RESET+ POWER- A.3.3 Internal USB 2.0 connector Internal USB 2.0 Connectors provides front USB 2.0 Header which require appropriate cable to support. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 120: Internal Usb 2.0 Vertical Connector

    USB2_12- USB2_13- USB2_7- USB2_8- USB2_12+ USB2_13+ USB2_7+ USB2_8+ A.3.4 Internal USB 2.0 Vertical Connector Internal USB 2.0 Vertical Connector provides two Type-A USB 2.0 Ports. USB 2.0 Vertical Connector Definition Definition S_USB_PN10 S_USB_PP10 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 121: Atx Power 4-Pin Connector

    ATX Power 8‐Pin Connector is for ATX PSU plug. Make sure you insert the ATX PSU plug on motherboard in the right orientation, otherwise the plug cannot be inserted. ATX 8-Pin Power Input Connector Definition Definition +12V +12V +12V +12V SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 122: Atx Power 24-Pin Connector

    +5V standby +12V +12V +3.3V A.3.8 Internal COM Connector Internal COM Connectors provides five ports which require appropriate cable to support: • COM2/5/6 support RS232 • COM3 supports RS232/RS422/RS485 • COM4 supports RS232/RS485 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 123 Receive data + (I) for full-duplex mode Receive data - (I) for full-duplex mode Ground RS485 Short description Meaning Data- Transmit / receive data - (I/O) for half-duplex mode Data+ Transmit / receive data+ (I/O) for half-duplex mode SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 124 JP6 (No Effect) COM3_PIN3: RS485+) JP7 (COM4 RS232/485 Select Jumper 3*2 Pin 2.54mm) Graphic Pin setting Function 1-3, 2-4 COM4: RS485 (COM4_PIN1: RS485- COM4_PIN3: RS485+) 3-5, 4-6(Default) COM4: RS232 (COM4_PIN1: DCD COM4_PIN3: RXD) SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 125 COM6_PIN8: + 12V 3-5, 4-6(Default) COM6_PIN1: DCD COM6_PIN8: RI JP12 (COM2 DCD/RI Select Jumper 3*2 Pin 2.54mm) Pin setting Function Graphic 1-3, 2-4 COM2_PIN1: + 5V COM2_PIN8: + 12V 3-5, 4-6(Default) COM2_PIN1: DCD COM2_PIN8: RI SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 126: M.2 Key M Slot

    Memory Modules. Refer to the chapter Installing memory module (Page 54) for detailed installation instruction. A.3.11 SATA 6.0 Gbps Port Connectors The motherboard provides four pieces of 7‐pin SATA Port Connectors, which support SATA devices through the connection of SATA Cable. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 127: Battery Socket

    Hardware description A.3 Internal Connector A.3.12 Battery socket The Battery Socket on the motherboard is for CR2032 Battery used for COMS data retention. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 128 Hardware description A.3 Internal Connector SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 129: Technical Support

    Please check regularly if updates and hotfixes are available for download to your device. The download area is available on the Internet at the following link: After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 130: Troubleshooting

    2. Set the date and the time in the "Main" tab. Time and date are wrong even The backup battery is dead. Replace the backup battery. after correctly setting them in the firmware (BIOS) SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 131: Problems When Booting The Device

    You can find the files and descriptions needed for GPT data storage medium is this on the supplied data storage medium. aborted with the following error message: "Status: 0xc0000225 Info: The boot selection failed because a required device is inaccessible" SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 132: Problems When Using Expansion Cards

    Different pin assignment expansion card and restart the device. If the error no longer occurs, the expansion card was the cause of the fault. Replace this with a Siemens expansion card or contact the supplier of the expansion card. If the device still crashes, contact your technical support team.
  • Page 133: Markings And Symbols

    Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical Eject CD/DVD isolation On/off switch, without electrical isolation SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 134: Certificates, Approvals And Markings

    Commission for the USA EFUP (Environment Friendly Use Approved for Korea Certification (KC) Period) marking for China Test mark of the Underwriters Disposal information, observe the Laboratories local regulations. Approval for India BIS Certification SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 135: Interfaces

    LAN interface, not approved for Line Out connecting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 136 Markings and symbols C.5 Interfaces SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 137: List Of Abbreviations

    Components sensitive to electrostatic charge European standard Hard Disk Drive Hard disk drive Height unit Input/Output Data input/output on computers iAMT Intel® Active Management Technology International Electrotechnical Commission Ingress Protection Degree of protection SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 138 Positive supply voltage of integrated circuits VEST Video Electronics Standards Association Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 139: Index

    Opening, 47 Connecting the function earth, 38 function earth, 38 Connections, (Interfaces) Connecting, 38 Country-specific information, 37 General technical specifications, 75 Data exchange, 41 Graphic controller, 81 Degree of protection, 76 Graphics memory, 81 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 140 Product label and component label, 33 Manuals, 9 PROFINET, 41 Memory modules Protection class, 76 Installing, 54 Protective measure Slots on motherboard, 81 Static electricity, 85 Microphone Connecting, 40 Module bracket, 53 Modules, 51 RAID, 131 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...
  • Page 141 Shutting down the operating system, 44 Switching on Switching on the device, 43 Telescopic rails Mounting holes, 36 Technical specifications (basic configuration), 82 Transportation, 24 UKCAI, 92 USB 2.0 Port, 116 USB 3.0 Interface, 116 SIMATIC IPC RW-543A Operating Instructions, 03/2023, A5E52332059-AA...

Table of Contents