8.3.2

Technical specifications DC power supply (DC)

Degree of protection
Protection class
Power supply characteristics
Input data
Voltage
Continuous current
Starting current (load-
independent)
Active power
Output data
Voltages
Power output
8.4

Electromagnetic compatibility

See the note in "Applicability of technical specifications (Page 68)".
Interference emission
Immunity to interference
Interference immunity on the
supply cables
Noise immunity on signal lines
Immunity to electrostatic dis-
charge
Immunity to RF interference
Immunity to magnetic fields
SIMATIC IPC BX-32A
Operating Instructions, 09/2023, A5E52798407-AB
I²t value:
Continuous power
Temporary power (30 s)
Peak power (10 ms)
IP20 (in installed state)
VDE 0106
DC power supply
Nominal 12/24 V DC, 9-36 V DC, not electrically isolated
Max. 40 A for 1.6 ms
Max. 25 A for further 4 ms
EN 61000-6-3, EN 61000-6-4, CAN/CSA CISPR32 Class B; KS C
9610-6-3, FCC Class A
EN 61000-6-1; EN 61000-6-2; KS C 9610-6-2
± 2 kV according to IEC 61000-4-4; burst
± 1 kV according to IEC 61000-4-5; symmetrical surge
± 2 kV according to IEC 61000-4-5; asymmetrical surge
± 1 kV acc. to IEC 61000-4-4; Burst; Length < 30 m
± 2 kV acc. to IEC 61000-4-4; Burst; Length > 30 m
± 2 kV acc. to IEC 61000-4-5; Surge; Length > 30 m
± 6 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
10 V/m 80 MHz – 2.7 GHz,
80% AM to IEC 61000-4-3
3 V/m 2.7 – 6 GHz,
80% AM to IEC 61000-4-3
10 V 10 kHz – 80 MHz,
80% AM to IEC 61000-4-6
100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)
Technical specifications
8.4 Electromagnetic compatibility
Max. 10.6 A
Max. 4.5 A²s
96 W
+12 V / 7.1 A
Max. 85 W
Max. 140 W
Max. 210 W