Siemens SIMATIC IPC RW-543A Operating Instructions Manual page 76

Table of Contents

Advertisement

Technical specifications
8.2 General technical specifications
Power consumption
Current output (DC)
Noise emission
Degree of protection
Safety
Protection class
Degree of pollution
Transient overvoltage
Safety regulations
76
350 W:
Typical load (100%, 350 W) at 82% efficiency
Typical load (50%, 175 W) at 85% efficiency
Light load (20%, 70 W) at 82% efficiency
500 W:
Typical load (100%, 500 W) at 82% efficiency
Typical load (50%, 250 W) at 85% efficiency
Light load (20%, 100 W) at 82% efficiency
850 W:
Typical load (100%, 850 W) at 87% efficiency
Typical load (50%, 425 W) at 90% efficiency
Light load (20%, 170 W) at 87% efficiency
350 W:
+5 V/16 A, +3.3 V/9 A
105 W permitted in total
+12 V1/17 A, +12 V2/17 A
-12 V/0.3 A, +5 VSB/2.5 A
The total sum of all voltages is max. 350 W
500 W:
+5 V/16 A, +3.3 V/19A
105 W permitted in total
+12 V1/20 A, +12 V2/20 A
-12 V/0.3 A, +5 VSB/2.5 A
The total sum of all voltages is max. 500 W
850 W:
+5 V/35 A, +3.3 V/20 A
200 W permitted in total
+12 V/70 A, -12 V/0.3 A
+5 VSB/3.0 A
The total sum of all voltages is max. 850 W
< 55 dB (A)
IP 20 for all enclosure according to IEC 60529
Protection class I compliant with IEC 61140
Device is designed for environments with pollution degree 2
Device is designed for connection to supply with overvoltage category II (transient
overvoltages up to 2500 V)
IEC/EN/UL 61010-1
IEC/EN/UL 61010-2-201
IEC/EN/UL 62368
CAN/CSA-C22.2 No. 61010-1
CAN/CSA-C22.2 No. 61010-2-201
Operating Instructions, 03/2023, A5E52332059-AA